6
Is the
inc. DS1
alarm still present?
If...
Then...
Yes
Continue with
No
Proceed to
............................................................................................................................................................
7
Is the alarm an
inc. DS1 LOF
?
If...
Then...
Yes
Determine and record the signal format
and the line code of the far-end port
connected to the alarmed port on the
Metropolis
®
DMXplore and then
continue with
No
Proceed to
............................................................................................................................................................
8
From the Metropolis
®
DMXplore System View, select
View
→
Equipment
. Expand the group (GRP) and VT group, then highlight
the alarmed DS1 port and click
Select
.
............................................................................................................................................................
9
Compare the signal format and the line code of the Metropolis
®
DMXplore port against the information determined about the far-end
port. If there are inconsistencies, determine the correct provisioning
and correct according to local procedures.
If the Metropolis
®
DMXplore port is provisioned incorrectly, from the
System View, select
Configuration
→
Equipment
. Expand the group
(GRP) and VT group, then highlight the alarmed DS1 port and click
Select
. Provision the Signal Format and the Line Code appropriately,
click
Apply
, and then click
Close
.
............................................................................................................................................................
10
From the System View, click the
Alarm List
button and click
Refresh
.
Procedure 5-23: Clear
″
inc. DS1
″
conditions/alarms
Trouble clearing procedures
....................................................................................................................................................................................................................................
365-372-333 R2.1
Issue 4, June 2005
Lucent Technologies
5 - 6 9