Procedure 5-1: Address communication failure with network
element
....................................................................................................................................................................................................................................
Overview
Use this procedure to address a communications failure with a
network element. It is assumed that any alarm-monitoring centers and
remote network elements have lost communication with the network
element.
Important! This procedure must be performed locally at the
network element.
Before you begin
Prior to performing this procedure:
1.
Refer to
and
in this chapter.
2.
Refer to
“Electrostatic discharge” (1-13)
in
Procedure
Complete the following steps to address a communication failure
with a network element.
............................................................................................................................................................
1
Observe the green power LEDs on the network element. Is at least
one green power LED lighted?
If...
Then...
Yes,
Continue with
No,
Proceed to
............................................................................................................................................................
2
Observe the LEDs on the SYSCTL circuit pack faceplate. Are the
LEDs constantly cycling?
If...
Then...
Yes,
Proceed to
No,
Continue with
Trouble clearing procedures
....................................................................................................................................................................................................................................