unexpected or failed Pluggable Transmission Module
....................................................................................................................................................................................................................................
unexpected or failed
Pluggable Transmission
Module
Internal equipment failure of the specified pluggable transmission
module was detected or communications problem between the
pluggable transmission module and the system controller (SYSCTL)
was detected.
Alarm Data
Value/Meaning
Reported Alarm
Level(s)
Critical (CR), Minor (MN)
AID (type)
Socket
Date
month/day/year that condition was detected
Time
hour:minute:second that condition was detected
Probable Cause
FACTERM
Effect on
Service
CR = SA
MN = NSA
Alarm Entity
Type
EQPT
Description
unexpected or failed Pluggable Transmission
Module failed
Likely Cause
An unprotected pluggable transmission module
failed or the wrong pluggable transmission module
was inserted into an unprotected socket - CR
(SA).
A protected pluggable transmission module failed
or the wrong pluggable transmission module was
inserted into a protected socket - MN (NSA).
Visible
indication
Lighted
CR/MJ
or
MN/ABN
LED on SYSCTL
faceplate, a continuously lighted port LED on the
failed socket, and a flashing
FAULT
LED on the
circuit pack.
Action
Proceed to
failed Pluggable Transmission Module
Alarms, conditions, and error messages
....................................................................................................................................................................................................................................
365-372-333 R2.1
Issue 4, June 2005
Lucent Technologies
3 - 9 1