MERLIN LEGEND Communications System Release 7.0
System Programming
555-670-111
Issue 1
April 1999
Programming Procedures
3-558
Automatic Route Selection
3
Facility Restriction Level
3
Use this procedure to assign a Facility Restriction Level (FRL) to each route. The
FRL ranges from 0 (least restrictive) to 6 (most restrictive) and is used to restrict
user access to the route. The FRL assigned to extensions and remote access
users is the opposite of the FRL assigned to routes, where 0 is the most restrictive
and 6 is the least restrictive.
NOTE:
Pool routes must be programmed before you assign Facility Restriction
Levels.
Facility Restriction Levels are assigned to Tables 1 through 18. Tables 17 and 18,
the Default Toll and Default Local tables respectively, cannot be changed.
Summary: Facility Restriction Level
3
Programmable by
System Manager
Mode
Hybrid/PBX
Idle Condition
Not required
Planning Form
3f, Automatic Route Selection Tables
3g, Automatic Route Selection Default and
Special Numbers Tables
Factory Setting
3 (beginning with Release 3.1, Table 18, the Default
Local table has a factory setting of 2)
Valid Entries
0 to 6
Inspect
No
Copy Option
No
Console Procedure
Tables
→
ARS
→
Sub
A
FRL
or More and
Sub
B
FRL
→
Dial table no. (1–18) and pool route no. (1–6)
→
Enter
→
Dial restriction level (0–6)
→
Enter
→
Exit
→
Exit
PC Procedure
→
→
or
%%
and
→
Type table no.
(1–18) and pool route no. (1–6)
→
→
Type
restriction level (0–6)
→
→
→