Lucent Technologies Lineage
®
2000 50A Ferroresonant Rectifier J85502B-1
Issue 6 May 1999
Spare Parts and Replacement Procedures 8 - 5
Modifying the
CM1 Option
Board
As described in schematic drawings SD-82604-01, replacement
CM1 option boards are supplied with all wire straps and
resistors in place. The same wire straps and resistors that were
removed from the original board must be removed from
replacement boards in order for the rectifier to operate properly.
Table 8-B and Figure 6-2 show the straps and resistors to keep
and to remove from the CM1 board for each option on the
J85502B-1 rectifier. The plug-in type wire straps are removed
completely from a 2-hole jack. The other wire straps shown are
soldered in and are never replaced once they are removed
Spare Fuses
Table 8-C provides spare fuse information for the J85502B-1
rectifier. A commercial equivalent fuse and the appropriate SD
sheets are referenced.
Replacing
Circuit Modules
This section gives step-by-step instructions for replacing circuit
modules CM1, CM2, and CM3.
Replacing CM1
Option Board
1. Turn the rectifier POWER switch Off.
2. Turn the rectifier (CBA1) DC OUTPUT circuit breaker
Off (down).
Table 8-C: Spare Fuse Information
List
Fuse
Designation
in SD
Drawing
Lucent
Technologies
Part Code
Rating
(amperes)
Commercial
Equivalent
Shown on
SD
Sheets
All
FA1 (+V)
70G
1/2
BUSSMANN*
70G
B3, C1
FA2 (-V)
*Bussmann is a trademark of the Bussmann Company.
Caution
Follow instructions above in “Handling Circuit Modules”
to minimize electrostatic discharge when handling circuit
modules.
Do not connect or disconnect circuit modules with
voltages present or equipment damage may occur.