ATM Services Configuration Guide for CBX 3500, CBX 500, GX 550, and B-STDX 9000
Configuring Management Paths
Using MSPVCs
4. Choose OK to save your selection. Continue with
to define the NMS path and static route.
Using MSPVCs
An MSPVC connects the switch management port to an SVC terminating address
located on an adjacent switch. This management connection is used as the NMS path,
which enables the NMS to manage the switch.
MSPVCs originate at an internal logical port located on the switch’s processor module
(either SP or NP, respectively). They terminate at the switch’s I/O interface: IOM for a
CBX, and BIO for the GX 550. MSPVCs are not supported on the B-STDX.
MSPVCs provide a data path that accesses internal network management functions.
The MSPVC internal logical port is designated as
MgmtLPort.SW<
switch name>
.
It uses an interface number (ifnum) of 4093. To form the MSPVC, connect the
MgmtLPort. SW<
switch name>
endpoint to any target ATM End System
Address (AESA) configured on an ATM UNI logical port.
Table 11-3.
Add Management VPI/VCI Dialog Box Fields
Field
Action/Description
Mgmt Connection
Name
Enter a unique, continuous, alphanumeric name to identify the
connection. Do not use hyphens, parentheses, or asterisks.
VPI (0..15)
Enter the VPI that is used for the connection.
Note: On a B-STDX switch, the VPI value defaults to zero (0)
and can not be modified.
VCI (32..1023)
Enter the VCI that is used for the connection.
Enable
Management
VPI/VCI
Select the check box to enable (default) the management
VPI/VCI connection to become activated when the switch or
port comes online.
If you do not want the management VPI/VCI to become
activated when the switch or port comes online, clear the check
box.