background image

NOTE

 – To comply with regulations, installation must be carried out 

by qualified electrician and in accordance with the current IEE Wiring 
Regulations (BS7671) and Building Regulations. A copy of the instructions 
must be left for the user/maintenance engineer for future reference.

ENSURE ELECTRICAL SUPPLY IS DISCONNECTED/
ISOLATED BEFORE COMMENCING INSTALLATION

INSTRUCTIONS FOR NEW INSTALLATIONS

1.  This luminaire requires a cut-out of 63 - 70mm, it is 

recommended that the luminaire is installed in a 67mm cut-out. 
The cut-outs need to be spaced to provide adequate clearance 
from beams, pipes and electrical cables.

2.  Twist bezel anti-clockwise to remove the bezel and LED module 

for installation.

3.  Insert ceiling bracket by lifting the springs to vertical and insert 

into ceiling cut-out. Ensure the bracket assembly is positioned 
centrally in the ceiling cut-out.

4.  Pull electrical cables through the bracket. Recommended 20mm 

of insulation and 5mm conductor length.

5.  Wire mains and lamp to terminal block, ensuring correct polarity 

of live/neutral. Downlight = Blue - Neutral, Brown - Live.

6.  Align points on the bezel to ceiling bracket springs, insert and 

rotate clockwise until tight.

7.  Re-instate power and test.

PART CODE: 

LFR5WH255D40 / LFR5PC255D40 / LFR5BS255D40 / LFR5PC250D27 / LFR5WH250D27 / LFR5BS250D27

LFR7WH475D40 / LFR7PC475D40 / LFR7BS475D40 / LFR7PC450D27 / LFR7WH450D27 / LFR7BS450D27

Tech Help Line

UK -

 0845 194 7584

Non UK -

 +44 (0)1952 238 100

Visit our website at

Luceco is a registered trade mark of Nexus Industries Ltd.

Supplied by

BG Electrical Ltd

Stafford Park 1 TF3 3BD ENGLAND

www.luceco.co

LED

 Fire Rated

Downlight

Installation & Operating Instructions

V2KS-01/2014

• 

Suitable for use with mains voltage of 180-240V AC.

• 

This luminaire is compatible with most leading edge dimmers such as BG Electrical Triac Dimmers; please 
check with dimmer manufacturer for compatibility with LED lighting, including min/max wattage loads.

• 

Luminaire is only suitable for covering with blanket/roll type loft insulation material only. 

• 

IP65 rated luminaires are protected against dust and jets of water; it is suitable for installation in bathroom 
zones 1 and 2 as defined by the IEE Wiring Regulations. IP65 only when installed as per instructions.

• 

This luminaire is only suitable for indoor use.

• 

This luminaire must be disconnected before insulation resistance testing of the lighting circuit.

• 

Check for electrical cables and pipes before installation.

CRI

   80

>

IP65

RATED

  7

GUARANTEE

year 

extended

90

min

FIRE RATED

60

min

FIRE RATED

30

min

FIRE RATED

50,000

HOURS

1

SCALE  1.000

3

SCALE  3.000

L

L

N

N

20mm

5mm

5

6

SCALE  1.000

4

SCALE  1.000

Cable

SCALE  1.000

Align 
points on 
the bezel 
to ceiling 
spring.

Mains

Downlight

2

67mm

Blue

Brown

Reviews: