Installation Instructions
4 |
P a g e
v 1 . 0 ( 0 9 / 2 0 1 9 )
SENSOR SWITCH SETTINGS:
DURATION TIME:
The time of the light remain switched on after activation can be adjusted from 8 secs to 3 mins. Adjust
the timer switch anti-clockwise to the minimum position then the fitting will activate and last 8 secs before turn off. Adjust
the timer switch clockwise to the maximum position then the fitting will activate and last 3 mins before turn off.
LUX LEVEL:
The lux control module has a built-in sensing device (photocell) that detects daylight and darkness. Adjust
the lux-level switch clockwise to the maximum position then the fitting will work at both day and night. Adjust the lux-level
switch anti-clockwise to the minimum position then it will only work at night.
NOTE: If you want to test the detection area of the PIR sensor, please wait for the ambient light level is below 30 lux.
MANUAL MODE (SENSOR OVERRIDE FUNCTION):
Manual mode is used when you would like the luminaire to be constantly on. The PIR sensor will be disabled and not
affected by the duration time and lux level settings.
1)
To switch into manual mode, turn on the wall switch twice within three seconds. (Wall switch action: OFF → ON →
OFF → ON.) The maximum duration for manual mode is 8 hours. Then the luminaire will be back into the sensor
mode automatically after the maximum duration.
2)
The manual mode can be stopped by turning the luminaire OFF then wait for 1 minute to switch the luminaire on
again. (Wall switch action: OFF → Wait for 1 minute → ON). The luminaire will be back into the sensor mode.
Safety tips
•
Always ensure the power is OFF and the luminaire has cooled down before performing any maintenance, cleaning,
or making any adjustment to the luminaire.
•
To avoid injury or damage to the luminaire, ensure that power leads and screws are secure before connecting the
power.
•
The luminaire must not be used if the shades has been cracked. Replace any cracked protective shield.
•
The light source of this luminaire is not replaceable; when the light source reaches its end of life the whole
luminaire shall be replaced.
•
Ensure that the luminaire does not come in contact with corrosive chemicals/solvents or abrasive cleaners etc.
•
To clean, wipe with a damp clean cloth. Do NOT soak or immerse the product in water or other liquids.
Specifications
SKU #
240812
Colour
Black
Rated Voltage
220-240V~ 50Hz
Rated Wattage
10W Max.
LED Specs
700 lumen, CCT 3000K/4000K, CRI > 80, Non-dimmable
IP Rating
IP54
PIR Sensor
Detection range & angle: Max.10M, 120°
Required installation height: 1.5 – 2.5M
Lux & Time adjustment:30 – 1000lux, 8s – 3min.
Weight
0.6kg
Dimensions
H:204mm W:120mm E:130mm