Installation Instructions 

 

3 | 

P a g e  

 

    v 1 . 0   ( 0 9 / 2 0 1 8 )

 

Clearance Information 

– AS/NZS 3000 Wiring Rules 

 

 

 

IC Rating 

– AS/NZS 60598.2.2 : 2016

 

1. A closed luminaire that allows building insulation to come into contact with its sides and to cover it. 

2. Type  IC-4  recessed  luminaire  can  be  used  together  with  building  insulation  that  can  safely  be 

exposed continuously to temperatures up to 90°C may abut and cover the luminaire; 

3. The declared IC-4 rating is based on the default testing ambient temperatures 25°C according to 

the standard. 

 

 

 

 

Safety tips 

 

Always ensure the power is OFF and the luminaire has cooled down before performing any maintenance, cleaning or 

making any adjustment to the fitting. 

 

To avoid injury or damage to the luminaire, ensure that power leads and screws are secure before connecting the 

power. 

 

Select a suitable location away from liquids and hazards. 

 

To clean, wipe with a soft damp cloth. Do NOT soak or immerse the luminaire in water or other liquids. 

 

Ensure that the luminaire does not come in contact with corrosive chemicals/solvents or abrasive cleaners etc. 

 

The light source in this luminaire is not replaceable; when the luminaire reaches its end of life the whole luminaire 

shall be replaced. 

LOCATION 

DISTANCE 

DESCRIPTION 

50 mm 

(Minimum) 

Clearance between the top of the recessed luminaire and any combustible materials, 

building elements or objects above it. 

50 mm 

(Minimum) 

Clearance between the side of the recessed luminaire and any combustible materials, 

building elements or objects. 

0 mm 

(Abutted) 

Insulation can be abutted against the side of recessed luminaire and covered as per   

IC Rating. See IC Rating section for more details. 

100mm 

Auxiliary equipment/driver/transformer must be placed 100mm away from the luminaire. 

It can be placed under the thermal insulation and covered. 

RISK OF FIRE

 – Required clearance from structural members and building elements 

SCB = 50 mm                      HCB = 50 mm 