C-2. Value Setting

The Meter allows the Operator to store 5 

different PRESET values (AUTO 1...AUTO 

4), which can be recalled without having to 

set them each time with the numeric keys.

Press and hold                  once to set the 

function.

The Meter will display:

                           Blinking

     Index of the PRESET value AUTO 1

When the value is blinking, press               to 

select preset 1-4, then press the numeric 

buttons to set the value.

Blinking message will be:

Press             to confirm the value and quit 

the setting mode, the setting value will be 

stored.

By holding on the keys the value continues 

to vary.

RESET

RESET

AUTO

AUTO

C-3. Unit Setting

The Meter allows the user to select one of 

the following measurement Units:

• QTS = QUARTS

• PTS = PINTS

• LIT = LITERS

• GAL = GALLONS (U.S. Gallons)

Press and hold                  two times to set 

the function. 

The Meter displays:

When the unit is blinking, press             to 

select unit L, GAL, PT or QT.

         

Press            to confirm the value and quit 

the setting mode, the setting value will be 

stored.

NOTE: 

The above mentioned measurement 

units refer to the Batch total indicators.

• If you select the unit LITERS, 

the TOTALS 

will be displayed in LITERS.

• If you select the unit GALLONS, PINTS or 

QUARTS, 

the TOTALS will be displayed 

in GALLONS.

• The modification of the measurement unit 

does NOT require a new calibration.

• If the TOTAL indicates a value other than 

zero, this value is automatically converted 

from one unit to another unit.

62.50

L

Lit

TOTAL

AUTO

62.50

L

Lit

TOTAL

AUTO

4see

62.50

L

Lit

TOTAL

AUTO

3see

AUTO

AUTO

AUTO

00.00

2see

L

Lit

AUTO

see

Lit

Blinking

see

Gal

PT

QT

Lit

OK/STOP

OK/STOP

OK/STOP

OK/STOP

OK/STOP

Attention: In order to preserve the unit setting,

                  must be hold for 2s after 

accomplishing setting and programme will be 

saved until the start of next function setting. 

If it is necessary to preserve the setting in 

flash in case of power-off, wait for 30s without 

operation until the screen disappears and the 

setting will be written in flash then.

OK/STOP

Summary of Contents for 1813351

Page 1: ...before operating Failure to follow the safety rules and other basic safety precautions may result in serious personal injury Save these instructions in a safe place and on hand so that they can be read when required Keep these instructions to assist in future servicing Oil Dispense Valve ...

Page 2: ...sing tools in confined work areas may put you in danger PERSONAL SAFETY Stay alert watch what you are doing and use common sense when operating this meter Do not use this meter while you are tired or under the influence of drugs alcohol or medication A moment of inattention while operating this meter may result in serious personal injury Dress properly Do not wear loose clothing dangling objects o...

Page 3: ...rts should be repaired or replaced immediately DO NOT exceed the maximum working pressure level of the lowest rates system component Use only extensions and nozzles that are compatible with this meter Use only fluids and solvents that are compatible with the equipment Notice the warnings for fluids and solvents Tighten all fluid connections before operating the meter Comply with all local state an...

Page 4: ...in valve in the system d Leave the drain valve open until ready to pressurize the system 2 Close the shutoff valve 3 Ground hoses and reels Grounding reduces the risk of static sparking ground all system components according to local state and federal codes Consult the user s manual on the pump and other system components to ground the following a Pump follow manufacturer s recommendations b Air a...

Page 5: ...e nozzle onto the meter screw it in tigtly with an open ended adjustable wrench 3 Open all dispense position shut offvalves start the pump to pressurize system 4 Before use to ensure accuracy purge all air from the fluid lines and dispense valve s 3 OPERATING THE METER WARNING After using the manual anti drip valve it is important to discharge the pressure between the chambers 1 and the manual val...

Page 6: ...ice center TECHNICAL DETAILS INTENDED USE FACTORY SETTINGS TOOL USE EXPLODED AND PARTS LIST OPERATION TROUBLE SHOOTING GUIDE E4 AUTO RESET OK STOP RESET RESET RESET RESET RESET RESET 62 50 3087 L Lit TOTAL 00 00 3087 L Lit TOTAL RESETABLE A Display Mode Start up the Meter by selecting The Meter displays Last amount dispensed Stored value Total Press and hold until the counter reads zero The Meter ...

Page 7: ...blinking Reset Batch Total AUTO 62 50L Lit TOTAL AUTO LASE 62 50L Lit TOTAL AUTO 4 62 50L Lit TOTAL AUTO 3 62 50L Lit TOTAL AUTO 2 AUTO AUTO AUTO AUTO 62 50L Lit TOTAL AUTO 00 00 308 70 L Lit AUTO OK STOP To start dispensing pull the trigger completely then release The trigger thus remains locked in open position Now dispensing can continue in AUTO mode Automatic stop The flow automatically stops ...

Page 8: ...s reached NOTE If you want to stop dispensing before the preset value is reached just press to stop B 4 Use The Trigger Fig A Pull the trigger completely to start dispensing and the trigger will lock when the desired amount has been pumped press the OK STOP button to release the trigger to stop the flow Fig B If there is only one indicator for the battery left you need to pull back the trigger man...

Page 9: ... displays When the unit is blinking press to select unit L GAL PT or QT Press to confirm the value and quit the setting mode the setting value will be stored NOTE The above mentioned measurement units refer to the Batch total indicators If you select the unit LITERS the TOTALS will be displayed in LITERS If you select the unit GALLONS PINTS or QUARTS the TOTALS will be displayed in GALLONS The mod...

Page 10: ...ustomize the Meter to select a PS factor between ZERO and FOUR C 4 Decimal Digits Setting Press and hold three times to set the function The Meter will display Blinking point When the number point is blinking press to select location of the point to confirm the number of decimal digits setting Press to confirm the value and quit the setting mode The setting value will be stored NOTE The Meter disp...

Page 11: ... a calibrated container Press and hold down six times to set the function The Meter will display Blinking point Press start the calibration by dispensing the fluid into a calibrated container During dispensing the Meter displays Batch Total dispensed Blinking AUTO The dispensing operation may be interrupted and resumed The calibrated dispensing is complete when the level of the fluid reaches the g...

Page 12: ...ill calculate the K Factor automatically which is blinking The Meter stores the new Calibration Factor K Factor and displays Blinking New K Factor After a few seconds the Meter automatically exits from the customization mode and starts using the new Calibration Factor One dispensing operation is enough to carry out the on site calibration of the meter If you wish to verify the result of this calib...

Page 13: ...e open the battery cover according to the photo shows 2 Pull out the battery electrode 3 Remove the used batteries 4 Install 1 new 1 Alkaline cell 9V 5 Replace the cover again The Meter will start automatically as soon as the battery pack is fixed carrying out a short SELF TEST Complete lighting of LCD Complete stop of LCD Display of serial number of electronic board Normal operation mode The repl...

Page 14: ...ENDED USE FACTORY SETTINGS TOOL USE EXPLODED AND PARTS LIST OPERATION TROUBLE SHOOTING GUIDE E12 EXPLODED AND PARTS LIST 3 2 4 6 1 27 28 26 25 7 22 29 23 19 20 39 8 9 10 12 31 33 30 18 14 46 35 41 36 37 38 21 44 42 34 40 45 ...

Page 15: ...ection Press RESET button 1 Press AUTO button and program batch size 2 Press RESET button 3 Check for battery icon Replace batteries Press RESET button Part No 1 2 3 4 6 7 8 9 10 12 14 18 19 20 21 22 23 25 26 Description Right cover Meter Cover Front Label Main Circuit Board Cross Recessed Pan Tapping Screw Rod Seat Washer Spring Swivel Trigger Mandril Screw Screw Cross Recessed Pan Tapping Screw ...

Page 16: ...Size 145x210mm REV 06 23 16 2 09 05 30 361 128克铜版纸 ...

Reviews: