background image

HEAVY DUTY OIL PUMP

MANUAL

171303
171305
171309

REV 01/12/15

1

WARNING SYMBOL

• This manual contains important warnings and information.

• Read and keep for reference.

CAUTION SYMBOL

This symbol alerts you to the possibility of serious injury or death if you do not follow the instructions.

CAUTION

This symbol alerts you to the possibility of damage to or destruction of equipment if you do not follow 

the instructions.

1 Summarize

1.1 Mainly propose

These pumps mainly provide power during oil transportation. Any other use maybe cause

un-safety problems and parts damage, fire explosion, and oil spark even serious fluid injection.

1.2 Description

1.2.1 Model: 3:1 Pneumatic Oil Pump

1.2.1.1 Specification: 36bar

Max. fluid working pressure

1.2.1.2 Configuration:

Sheet 1: 3:1 Pneumatic Oil Pump

Remark: with 3/4"M to 1/2"F reducer.

1.2.1.3 Max. free flow rate: 45L/min.

1.2.2 Model: 5:1 Pneumatic oil pump

1.2.2.1 Specification: 60bar

Max. fluid working pressure

1.2.2.2 Configuration:

Sheet 2: 5:1 Pneumatic oil pump

Remark: with 3/4"M to 1/2"F reducer.

1.2.2.3 Max. free flow rate: 40L/min.

Model

1/4"quick plug

1/4"NPT

270mm
730mm
940mm

1190mm

Air inlet

Length

of

suction

tube

17130301 17130303 17130331 17130333 17130361 17130363 17130371 17130373

Model

1/4"quick plug

1/4"NPT

270mm
730mm
940mm

1190mm

Air inlet

Length

of

suction

tube

17130501 17130503 17130531 17130533 17130561 17130563 17130571 17130573

Summary of Contents for 171303

Page 1: ...ark even serious fluid injection 1 2 Description 1 2 1 Model 3 1 Pneumatic Oil Pump 1 2 1 1 Specification 36bar Max fluid working pressure 1 2 1 2 Configuration Sheet 1 3 1 Pneumatic Oil Pump Remark with 3 4 M to 1 2 F reducer 1 2 1 3 Max free flow rate 45L min 1 2 2 Model 5 1 Pneumatic oil pump 1 2 2 1 Specification 60bar Max fluid working pressure 1 2 2 2 Configuration Sheet 2 5 1 Pneumatic oil ...

Page 2: ...ent Tighten all fluid connections before operating the equipment Check the hoses tubes and couplings daily Replace worn or damaged parts immediately Do not repair high pressure couplings you must replace the entire hose 3 1 3 4 MOVING PARTS HAZARD Moving parts can pinch or amputate your fingers Do not operate the pump with the air motor plates removed Keep clear of all moving parts when starting o...

Page 3: ...ke sure the max work pressure for each device Rated pressure in the system can not exceed the max pressure of any device Or there will be burst explosion malfunction serious damage 5 3 3 2 3 Remind Pump can not operate with empty load Or the speed will be very fast which will self damage If acceleration is too fast or running very slow Should stop operation and check that if there is enough oil in...

Page 4: ...p O ring Suction tube Steel ball Oil inlet valve Extension tube Filter Piston shaft Left silencer Transfer slipcover Rod Screw Part No 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 Description O ring Piston Pin O ring Rope shaft Spring O ring Jar body Washer Steel wire Nut Cushion Rod Seal Quick plug Oil outlet Gasket Screw Screw Bolt Adjustable nut Nut Bung adapter...

Page 5: ...ring Piston Circlip Suction tube O ring Oil inlet valve Extension tube Filter Piston shaft Left silencer Transfer slipcover Rod Screw O ring QTY 1 2 1 2 1 1 1 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 6 1 Description Piston Pin O ring Rope shaft Spring O ring Jar body Washer Steel wire Nut Cushion Rod Seal Quick plug Oil outlet Gasket Screw Screw Bolt Adjustable nut Nut Bung adapter Label O ring Steel bal...

Page 6: ... 4 Cnnect the rigid suction 8 to the end of the flexible suction tube 6 using the elastic clamp provided 5 Put the bung adapter 7 into the drum hole 6 Put the rigid suction tube 8 into the pump and secure it in place Limited Warranty 1 The manufacturer warrantees this product against defects in material and craftsmanship for a period of 36 months from date of purchase but not including wearing par...