2.2.3 Lightning Protection 

In thunderstorm weather, a sudden strong current may damage the switch. To protect your switch 

from lightning strike or strong current, please: 

 

Make sure the switch, rack, installa

ti

on desktop, and power socket on the wall all are 

well-grounded. 

 

Route the switch cables properly. 

 

If you need to route cables outdoors, it is advised to use a lightning arrester. 

2.2.4 Installation Position 

No ma

tt

er whether your switch is installed on a rack or desktop, follow the instruc

ti

ons below: 

 

Make sure the rack or desktop be stable and 

rm enough. 

 

The room must be well-ven

ti

lated. Keep at least 10 cm distance between all sides for cooling. 

 

Do not place any heavy or big-size object on the switch. 

 

Keep at least 1.5 cm ver

ti

cal distance between each switch while installing it on a rack. 

2.3 Installation 

POE-SW1602N and POE-SW2402N  switches support rack installa

ti

on. Follow the steps below for 

rack installa

ti

on

.   

 

The following panel is the front panel of the switch. For details about the ports, see 

secti

on 

Appearance

. 

Step 1

 

Check the grounding and stability of the rack. 

Step 2

 

Use the a

tt

ached screws to 

x two L-shaped brackets to the sides of the switch. 

 

Figure 2-1

 

Install L-Shaped Bracket 

Step 3

 

Place your switch on the rack, 

x it to the rack with self-prepared screws, and ensure the 

stable installa

ti

on of your switch to the rack.   

Summary of Contents for POE-SW1602N

Page 1: ...16 24 Port 100M Long Range PoE Switch Quick Start Guide...

Page 2: ...and Cautionary Tips 5 2 2 Working Environment Requirements 5 2 2 1 Temperature and Humidity 5 2 2 2 Static Electricity Protection 5 2 2 3 Lightning Protection 6 2 2 4 Installation Position 6 2 3 Inst...

Page 3: ...NG TO THE PRODUCT WITH INTERNET ACCESS THE USE OF PRODUCT SHALL BE WHOLLY AT YOUR OWN RISKS OUR COMPANY SHALL NOT TAKE ANY RESPONSIBILITES FOR ABNORMAL OPERATION PRIVACY LEAKAGE OR OTHER DAMAGES RESUL...

Page 4: ...ul interference 2 This device must accept any interference received including interference that may cause undesired operation EU Conformity Statement This product and if applicable the supplied access...

Page 5: ...nt You shall acknowledge that the use of the device with Internet access might be under network security risks please strengthen protection for your personal information and data security If you nd th...

Page 6: ...of multi channel video data With high reliability convenience for installation and maintenance quick switch function and multi port the switches are applicable to device access in small scaled local a...

Page 7: ...402N Figure 1 2 POE SW2402N Front Panel Indicator Indicators are used to monitor the status of switches See the following table for the description of the indicators Table 1 2 Indicator Description In...

Page 8: ...on Standard The corresponding port supports network transmission of up to 100 m and the speed rate of the port is 100 Mbps Extend POE SW1602N Extend 9 16 POE SW2402N Extend 17 24 The 9 to 16 ports of...

Page 9: ...shown as below Rear Panel of POE SW1602N and POE SW2402N Figure 1 3 POE SW1602N and POE SW2402NRear Panel Grounding Terminal The grounding terminal connects with ground cable in case of lightning For...

Page 10: ...working and operation life of the switch room temperature and humidity must be kept at certain level If room humidity is too high for a long time insulating materials may be ineffective or even lead t...

Page 11: ...and rm enough The room must be well ventilated Keep at least 10 cm distance between all sides for cooling Do not place any heavy or big size object on the switch Keep at least 1 5 cm vertical distanc...

Page 12: ...e overvoltage and overcurrent induced by lightening for switch and to protect personal safety Select the appropriate grounding method according to your needs 2 4 1 With Grounding Bar If a grounding ba...

Page 13: ...nd the grounding body is allowed to be buried follow the steps below Step 1 Bury an angle steel or steel pipe 0 5 m into the mud land Step 2 Weld one end of the grounding cable to the angle steel or s...

Page 14: ...00M Combos This section uses dual fiber SFP optical module as an example When connected to a network cable the 1000M combo is a PoE port When plugged into with an optical module and connected to an op...

Page 15: ...cator is lit the link is connected If the indicator is unlit the link is disconnected Check the line and make sure opposite devices have been started For more details see section Indicator 3 3 Checkin...

Reviews: