background image

LT-424-UC

DALI 

Push 

Switch

COM

IN4

IN3

IN2

IN1

DA

DA

Switch Type

2

DALI Bus Power Supply

DALI

-

PS

-

MINI

L N

100

-

240V

 

AC

DALI 

BUS

DALI Bus

Digital touch switch

Connections

Update Time: 2015.06.15

Reset switch

Reset Switch

Doorbell switch

1. Disconnect the power supply of all devices on the DALI bus before installing. 

Installation: 

Note: This product is only suitable for the reset switch. It can be Key 1, Key 2, Key 3 or Key 4.

If the switch failure occurs after pressing, 

1. If the connection is correct; 

2. Make sure to use the reset switch; 

3. Check if the DALI power output is stable.

please check: 

Troubleshooting:  

3. Open the shell, set up the address.

2. Connect according to the above wiring diagram. DALI bus does not distinguish plus-minus polarity. Meanwhile connected

    to the reset switch.

Address

Short Press: Press and release in 1 second to turn on/off. 

Long Press: Press for more than 1

for dimming, first long press is increase brightness, 

                      release and long press again is decrease brightness. 

 second 

DALI Dimming Driver