5.22 Parameter Lock
Use parameter view lock to hide parameters after registering and entering a user
password.
Group
Code
Name
Setting
Setting
Range
Unit
dr
94
Password registration
-
0
–9999
-
95
Parameter lock settings
-
0
–9999
-
Parameter Lock Setting Details
Code and
Features
Description
dr-94
Register a password to prohibit parameter modifications. Follow the
procedures below to register a password.
Step
Procedures
1
Press the [ENT] key on dr-94 code and the saved password
input window will be displayed. If password registration is
being made for the first time, enter 0. It is the factory default.
2
If a saved password has been set, enter the saved password.
3
If the entered password matches the saved password, then a
new window to enter a new password will be displayed. (The
process will not move to next stage until the user enters a
valid password).
4
Register a new password.
5
After registration, Code dr-94 will be displayed.
dr-95
Press the [ENT] key when the change prevention feature is disabled,
and UL (Unlocked) is displayed. Press the [ENT] key again a field to
input password is shown. Enter the password and the Locked display
is shown. Even if you press [ENT] key from the function code to
change the changing the parameter, this will not be changed to edit
mode. Enter password again to display UL (Unlocked). The change
prevention feature is disabled.
If parameter view lock and parameter lock functions are enabled, no inverter operation
related function changes can be made. It is very important that you memorize the
password.
Summary of Contents for G100
Page 14: ......
Page 16: ...5 5 7 5 kW 3 Phase ...
Page 32: ...0 4 0 8 kW 1 5 2 2 kW 4 0 kW ...
Page 48: ......
Page 68: ......
Page 81: ......
Page 100: ......
Page 116: ...trips automatic Reset Restart is not attempted and the Fire Mode Count is not increased ...
Page 118: ......
Page 130: ... Terminal connections for 3 wire operation 3 wire operation ...
Page 140: ... PID control block diagram ...
Page 165: ...Code and Features Description Code Description continuous rating ...
Page 170: ......
Page 186: ... Displayed as on the Keypad ...
Page 200: ...provided signal output at 150 36 sec ...
Page 216: ...Code and Features Description delay time delay time ...
Page 219: ......
Page 237: ......
Page 253: ......
Page 295: ......
Page 314: ......
Page 335: ...Manual Revision History Revision History No Date Edition Changes 1 2019 01 First Release ...