background image

LSI Corporation  

December 2010

Page 9

MegaRAID SAS 9265-8i RAID Controller Quick Installation Guide

Supported RAID Levels

8.

Run the WebBIOS Configuration Utility

 

Run the WebBIOS Configuration Utility to configure the groups and the virtual 
drives. When the message 

Press <Ctrl><H> for WebBIOS

 appears on the 

screen, immediately press CTRL+H to run the utility. 

NOTE:

Refer to the

 

MegaRAID SAS Software User Guide

 for detailed steps on 

configuring groups and virtual drives.

9.

Install the Operating System Driver

 

The controller can operate under various operating systems, but you must install 
the software drivers first.

The 

MegaRAID Universal Software Suite 

CD includes the software drivers for the 

supported operating systems, along with documentation. You can view the 
supported operating systems and download the latest drivers for RAID controllers 
from the LSI web site at: 

http://www.lsi.com/cm/DownloadSearch.do

. Access the 

download center, and follow the steps to download the driver.

Refer to the 

MegaRAID SAS Device Driver Installation User Guide

 on the 

MegaRAID Universal Software Suite

 CD for more information about installing the 

driver. Be sure to use the latest service packs that are provided by the operating 
system manufacturer and to review the 

readme

 file that accompanies the driver.

Supported RAID Levels

This RAID controller supports drive groups using the following RAID levels:

RAID 0 (data striping):

 Data is striped across all drives in the group, enabling very 

fast data throughput. There is no data redundancy. All data is lost if any drive fails.

RAID 1 (drive mirroring):

 Data is written simultaneously to both drives in the drive 

group, providing complete data redundancy if one drive fails. RAID 1 supports an 
even number of drives from 2 to 32 in a single span.

RAID 5 (drive striping with distributed parity):

 Data is striped across all drives in 

the group. Part of the capacity of each drive stores parity information that 
reconstructs data if a drive fails. RAID 5 provides good data throughput for 
applications with high read request rates.

RAID 6

 

(drive striping with distributed parity across two drives): 

Data is striped 

across all drives in the group and two parity drives are used to provide protection 
against the failure of up to two drives. In each row of data blocks, two sets of parity 
data are stored.

RAID 00 (data striping across RAID 0 drive groups): 

RAID 00 is a spanned drive 

group that creates a striped set from a series of RAID 0 drive groups.

RAID 10 (RAID 1 and RAID 0 in spanned groups):

 RAID 10 uses mirrored pairs of 

drives to provide complete data redundancy. RAID 10 provides high data 
throughput rates.

RAID 50 (RAID 5 and RAID 0 in spanned groups):

 RAID 50 uses both parity and 

drive striping across multiple drives to provide complete data redundancy. RAID 50 
provides high data throughput rates.

Summary of Contents for MegaRAID SAS 9265-8i

Page 1: ...49754 00A MegaRAID SAS 9265 8i RAID Controller Quick Installation Guide 49754 00 Revision A December 2010...

Page 2: ...ration The information contained herein is not to be used by or disclosed to third parties without the express written permission of LSI Corporation Corporate Headquarters Email Website Milpitas CA gl...

Page 3: ...Overview The MegaRAID SAS 9265 8i RAID controller is a PCI Express low profile RAID controller that offers a 6 Gb s transfer rate It controls eight internal SAS SATA ports through two SFF 8087 mini SA...

Page 4: ...the following documentation MegaRAID 6Gb s SAS RAID Controllers User Guide MegaRAID SAS Software User Guide MegaRAID SAS Device Driver Installation User s Guide Cache Backup Products for MegaRAID SAS...

Page 5: ...e fault LED header 2 pin connector Connects to an LED that indicates whether a drive is in a fault condition J1A2 Write pending LED header 2 pin connector Connects to an LED that indicates when the da...

Page 6: ...connector Supports SES SCSI enclosure services over I2 C through an internal I2 C backplane cable J1B1 Serial EEPROM SBR 2 pin connector Provides controller information such as the serial number revis...

Page 7: ...rd for information about the PCI Express slot Figure 3 Installing the MegaRAID SAS 9265 8i RAID Controller J2B4 Standard edge card connector The RAID controller interfaces with the host system through...

Page 8: ...ons NOTE Refer to the MegaRAID 6Gb s SAS RAID Controllers User Guide on the MegaRAID Universal Software Suite CD for detailed information about the SAS cables 7 Turn on the Power to the Computer Reins...

Page 9: ...els This RAID controller supports drive groups using the following RAID levels RAID 0 data striping Data is striped across all drives in the group enabling very fast data throughput There is no data r...

Page 10: ...sistance in installing configuring or running the MegaRAID SAS 9265 8i RAID controller contact an LSI Technical Support representative Click the following link to access the LSI Technical Support page...

Page 11: ......

Page 12: ......

Reviews: