background image

2-16

Installing the LSI20160

Copyright © 2001 by LSI Logic Corporation. All rights reserved.

2.2.5.1 Internal SCSI Terminations

If you are making internal SCSI device connections on your host adapter,
you must terminate the last internal device on the SCSI bus. You must
disable the termination on all other devices. Termination on your host
adapter is automatically enabled in this case if there are no external
SCSI devices connected through J2.

Figure 2.12

shows an example of how termination is determined for this

SCSI bus configuration.

Figure 2.12 Internal SCSI Device Termination

Host Adapter
Automatically
Terminated

Last Device on

Chain-

Termination

Enabled

Does Not End Chain-

Termination Disabled

Summary of Contents for LSI20160

Page 1: ...DB15 000231 00 LSI20160 Single Channel Ultra160 SCSI to PCI Host Adapter USER S GUIDE Version 1 0 D e c e m b e r 2 0 0 1...

Page 2: ...tion between the equipment and the receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV techn...

Page 3: ...ions releases of this product until rescinded by an update To receive product literature visit us at http www lsilogic com LSI Logic Corporation reserves the right to make changes to any products here...

Page 4: ...iv Copyright 2001 by LSI Logic Corporation All rights reserved...

Page 5: ...have some familiarity with SCSI protocol and related support devices and will benefit persons installing and using the LSI20160 Organization This document has the following chapters and appendix Chap...

Page 6: ...Related Publications PCI Storage Device Management System SDMS 4 0 User s Guide Version 11 Order Number S14007 B LSI53C1000 PCI to Ultra160 SCSI Controller Technical Manual Version 2 1 Order Number S...

Page 7: ...CRC 1 5 1 3 3 Asynchronous Information Protection AIP 1 5 1 4 SureLINK Ultra160 SCSI Domain Validation Benefits 1 5 1 5 LVDlink Technology Benefits 1 5 1 6 TolerANT Technology Benefits 1 6 Chapter 2...

Page 8: ...mospheric Characteristics 3 3 3 1 4 Electromagnetic Compliance 3 3 3 1 5 Safety Characteristics 3 3 3 2 Operational Environment 3 4 3 2 1 The PCI Interface 3 4 3 2 2 The SCSI Interface 3 7 3 2 3 The L...

Page 9: ...able to Internal SCSI Device Connection 2 8 2 6 Connecting Additional Internal SCSI Devices 2 9 2 7 Multiple Internal SCSI Devices Chained Together 2 10 2 8 SCSI LED Connector 2 11 2 9 External Cable...

Page 10: ...x Copyright 2001 by LSI Logic Corporation All rights reserved...

Page 11: ...l rights reserved Tables 2 1 SCSI ID Record 2 19 3 1 Maximum Power Requirements 3 2 3 2 PCI Connector J1 Front 3 5 3 3 PCI Connector J1 Back 3 6 3 4 SCSI Interface 3 7 3 5 LED Connector J3 Pinout 3 8...

Page 12: ...xii Copyright 2001 by LSI Logic Corporation All rights reserved...

Page 13: ...ion The LSI Logic LSI20160 provides one SCSI 3 Ultra160 SCSI interface to PCI computer systems that require BIOS support on the add in SCSI adapter Installing this adapter in your PCI system allows co...

Page 14: ...n overview of the PCI interface the SCSI interface and board characteristics for the LSI20160 1 2 1 PCI Interface The PCI interface operates as a 32 bit DMA bus master where the connection is made thr...

Page 15: ...ility Ultra160 SCSI LVD synchronous transfers at up to 160 Mbytes s Supports Domain Validation Double Transition DT data transfers and Cyclic Redundancy Check CRC Supports variable block size and scat...

Page 16: ...aft standard that allows faster synchronous SCSI data transfer rates than Ultra2 SCSI When enabled Ultra160 SCSI performs 80 megatransfers per second resulting in approximately double the synchronous...

Page 17: ...I implementations by extending the Domain Validation guidelines documented in the ANSI T10 SPI 3 specifications Domain Validation verifies that the system is capable of transferring data at Ultra160 s...

Page 18: ...rs The benefits of TolerANT technology include increased immunity to noise when the signal is going HIGH better performance due to balanced duty cycles and improved fast SCSI transfer rates In additio...

Page 19: ...er installation and SCSI bus setup experience this section may sufficiently describe the procedure for you If you prefer more detailed guidance for installing the LSI20160 proceed to Section 2 2 Detai...

Page 20: ...system 2 2 Detailed Installation Procedure This section provides step by step instructions for installing the LSI20160 and connecting it to your SCSI peripherals If you are experienced in these tasks...

Page 21: ...nd unplug the system Step 4 Remove the cabinet cover on your computer to access the PCI slots Caution Ground yourself by touching a metal surface before handling boards Static charges on your body can...

Page 22: ...e PCI slot Make sure the edge connector is properly aligned before pressing the board into place The bracket around connector J2 should fit where the blank bracket panel was removed Refer to Figures 2...

Page 23: ...on All rights reserved Step 3 Secure the bracket with the bracket screw before making the internal and external SCSI bus connections Figure 2 2 shows an example on how to insert your host adapter Figu...

Page 24: ...1 side The connectors on this cable are keyed to ensure proper pin 1 connection Some internal cables come with an LVD SE terminator on one end This end should be furthest from the host adapter All ex...

Page 25: ...tep by step instructions for making internal SCSI bus connections If you only have external connections skip to Section 2 2 4 3 Making External SCSI Bus Connections Step 1 Plug a 68 pin connector on t...

Page 26: ...SCSI connector on the internal SCSI device Pin 1 must match on all connections The lead in the cable adjacent to pin 1 is colored Figure 2 5 illustrates a connection to an internal SCSI device Figure...

Page 27: ...rved Step 3 Plug in any additional internal SCSI devices as required Refer to the example in Figure 2 6 Figure 2 7 illustrates the connection of multiple internal SCSI devices chained together Make su...

Page 28: ...ed to an existing IDE controller If you want you can connect the LED to the SCSI LED connector Connect the LED cable to J3 on your SCSI host adapter as shown in Figure 2 8 The Busy LED connector J3 is...

Page 29: ...Logic Corporation All rights reserved After the correct connection is established the front panel LED indicates activity on the SCSI bus Refer to Table 3 5 on page 3 8 for connector pinout informatio...

Page 30: ...by step instructions for making external SCSI bus connections Step 1 Plug the 68 pin VHDCI connector on one end of a shielded external high density cable see Figure 2 3 into the host adapter connecto...

Page 31: ...n All rights reserved Step 2 Plug the 68 pin connector on the other end of the shielded external SCSI cable into the SCSI connector on your external SCSI device Figure 2 10 illustrates a connection to...

Page 32: ...oration All rights reserved Step 3 Chain any additional SCSI devices together with shielded external SCSI cables Figure 2 11 shows an example of multiple external SCSI devices that are chained togethe...

Page 33: ...he terminator is disabled Termination can be enabled or disabled for a specific channel using software control with GPIO3 LVD peripheral devices are normally terminated with external terminators but a...

Page 34: ...SI bus You must disable the termination on all other devices Termination on your host adapter is automatically enabled in this case if there are no external SCSI devices connected through J2 Figure 2...

Page 35: ...bus Termination on all other devices must be disabled Termination on your host adapter is automatically enabled in this case if there are no internal devices connected through J4 Figure 2 13 shows an...

Page 36: ...e Device Management System SDMS 4 0 User s Guide explains how to set your host adapter ID using the SCSI BIOS Configuration Utility The peripheral device SCSI IDs are usually set with jumpers or with...

Page 37: ...Detailed Installation Procedure 2 19 Copyright 2001 by LSI Logic Corporation All rights reserved Table 2 1 SCSI ID Record SCSI ID SCSI Device 15 14 13 12 11 10 9 8 7 LSI20160 default 6 5 4 3 2 1 0...

Page 38: ...puter Step 3 Wait for your computer to boot up Step 4 Refer to the LSI Logic PCI Storage Device Management System SDMS 4 0 User s Guide or the guide for the software you will use to load the driver so...

Page 39: ...ty characteristics of the LSI20160 Additionally this board is compliant with electromagnetic standards set by the FCC 3 1 1 Physical Characteristics The dimensions of the LSI20160 are 4 721 x 2 536 in...

Page 40: ...onnector J2 68 pin VHDCI connector for external SCSI connection J4 68 pin high density internal SCSI connection J3 4 pin low density unshrouded right angle LED connector Subsystem Vendor ID is 1000 Su...

Page 41: ...ure 32 C The following parameters define the storage and transit environment for the LSI20160 Temperature range 45 C to 105 C dry bulb Relative humidity range 5 to 90 noncondensing 3 1 4 Electromagnet...

Page 42: ...open boot code support through PCI and a serial EEPROM 3 2 1 The PCI Interface The PCI interface operates as a 32 bit DMA bus master The connection is made through edge connector J1 which provides con...

Page 43: ...3 3 V 36 5 V 6 DEVSEL2 37 INTB2 7 GND2 38 INTD2 8 LOCK2 39 GND PRSNT12 9 PERR2 40 RESERVED 10 3 3 V 41 GND PRSNT22 11 SERR2 42 KEYWAY 12 3 3 V 43 KEYWAY 13 C_BE12 44 RESERVED 14 AD14 45 GND 15 GND 46...

Page 44: ...35 5 V 5 TRDY2 36 INTA2 6 GND 37 INTC2 7 STOP2 38 5 V 8 3 3 V 39 RESERVED 9 SDONE 40 3 V 5 V 10 SBO2 41 RESERVED 11 GND 42 KEYWAY 12 PAR 43 KEYWAY 13 AD15 44 RESERVED 14 3 3 V 45 RST2 15 AD13 46 3 V 5...

Page 45: ...onnector J4 makes the internal connection which only provides LVD SCSI termination Table 3 4 shows the signal assignments for J2 and J4 Table 3 4 SCSI Interface Signal Name Pin Signal Name Pin Signal...

Page 46: ...ss to the board The GPIO0_FETCH line has a maximum output low voltage of 0 4 V and minimum output low current of 16 mA It is driven low to complete the circuit when a harness with an LED is attached T...

Page 47: ...ains the ID numbers During system initialization the system loads the ID numbers into the Subsystem Vendor ID and Subsystem ID registers of the LSI20160 SCSI Controller the LSI53C1000 For more informa...

Page 48: ...3 10 Technical Specifications Copyright 2001 by LSI Logic Corporation All rights reserved...

Page 49: ...nchronous Information Protection provides error checking for asynchronous nondata phases of the SCSI bus Asynchronous Data Transfer One of the ways data is transferred over the SCSI bus It is slower t...

Page 50: ...ta transfers CRC is used on the Double Transition DT Data In and DT Data Out phases CPU Central Processing Unit The brain of the computer that performs the actual computations The term Microprocessor...

Page 51: ...Ultra SCSI Fast 40 The SCSI Trade Association STA supports the use of Ultra2 SCSI over the term Fast 40 Please see Ultra2 SCSI Fast SCSI A standard for SCSI data transfers It allows a transfer rate of...

Page 52: ...ogical Unit Number An identifier zero to seven for a logical unit LVDlink Low Voltage Differential link allows greater Ultra2 SCSI device connectability and longer SCSI cables LVDlink lowers the ampli...

Page 53: ...gn standards that developers must comply with to be Windows NT compatible PCI Peripheral Component Interconnect A local bus specification that allows connection of peripherals directly to computer mem...

Page 54: ...inal standard is referred to as SCSI 1 SCSI 2 The SCSI specification which adds features to the original SCSI standard SCSI 3 The SCSI specification which adds features to the SCSI 2 standard SCSI Bus...

Page 55: ...ty checking Basic level 1 Enhanced level 2 and Margined level 3 Synchronous Data Transfer One of the ways data is transferred over the SCSI bus Transfers are clocked with fixed frequency pulses This i...

Page 56: ...High Density Cable Interconnect Virtual Memory Space on a hard disk that can be used as if it were RAM Wide SCSI A SCSI 2 feature allowing 16 bit or 32 bit transfers on the SCSI bus This dramatically...

Page 57: ...compliance 3 3 external SCSI bus connections external chaining 2 14 making 2 12 to external device 2 13 external SCSI terminations 2 17 F features board characteristics 1 4 3 1 PCI interface 1 2 3 4...

Page 58: ...connections 2 7 to 2 10 plug and play 1 3 receivers input signal filtering 1 6 SE or LVD termination 3 7 setting IDs 2 18 termination power 1 3 SCSI BIOS configuration utility using 2 18 serial EEPROM...

Page 59: ...ease copy the following page add your comments and fax it to us at the number shown If appropriate please also fax copies of any marked up pages from this document Important Please include your name p...

Page 60: ...nt please specify the error and page number If appropriate please fax a marked up copy of the page s Please complete the information below so that we may contact you directly for clarification or addi...

Page 61: ...You can find a current list of our U S distributors international distributors and sales offices and design resource centers on our web site at http www lsilogic com contacts na_salesoffices html...

Page 62: ......

Reviews: