©2011 LSI Industries Inc.
442652 Rev. 1/11
3 / 3
LSI Industries Inc. 10000 Alliance Road Cincinnati, Ohio 45242 (513) 793-3200 Fax (513) 793-0147 www.lsi-industries.com
Installation Questions?
Call LSI Field Service Department at:
1-800-436-7800 Ext. 3300
Fax: 1-877-861-1368
DOUBLE-DECK CROSSOVER
®
SERIES LUMINAIRE
, cont'd.
Using Clasp on the end of the Tether, attach Luminaire to
Mounting Bracket through rectangular hole. Allow Luminaire
to hang by Tether for wiring. Run supply wiring to box
bottom.
NOTE: K.O.'s are 1/2" conduit size.
Make all
primary wire connections. Flip Driver Box Cover top
closed. Ensure all wiring is inside box and that no wires are
pinched. Make sure wire tie keeps wires together to prevent
pinching! Secure cover to box bottom with side screw.
Leaving Tether attached, lift Luminaire up through the Collar.
Position Luminaire over Mounting Bracket. Secure Luminaire
with (4) #10-24 x 1" screws and tighten. (Note keyhole slots
on opposite corners).
NOTE: if installing Focus (CRR3 FO) model, ensure light
bars point towards pump!
If installing Focus (CRR3 FO) model, adjust each light strip
until satisfied. Use a 7/32" rounded Allen key. A 5.5 mm
Allen key will work as well.
Clasp
Luminaire
Mounting
Bracket
Tether
4
5
#10-24 x 1"
Screw
Luminaire
Driver