Power supply
Voltage
6 ÷ 30 Vdc
Inputs
•
Separated by powering 6 ÷ 30 Vdc:
•
From solar panel (17 Vmin); maximum input current 5 A;
charge voltage 13.8 V
•
From battery /power grid; maximum current 5 A
Voltage capacity
pulse peak
400 W
pulse dissipation’s peak power capacity with
10/1000
waveform
Repetition rate (duty cycle): 0.01 %
Battery charger
17 V min
Protections
•
IEC-61000-4-2 ESD 30 kV (air), 30 kV (contact)
•
Protection against self-restorable PTC fuses
overcurrent
•
Reverse polarity protection
•
Power input overvoltage protection over 33 V
•
400 W pulse dissipation’s peak power capacity with
10/1000 waveform.
Environmental
limits
Operative
temperature
-30 ÷ 60 °C
Operative humidity 10 ÷ 99 % RH, without condensation (
conformal coating
option)
Storage
temperature
-40 ÷ 80 °C
Physical
parameters
Weight
600 g
Dimensions
160 x 125 x 50 mm
Mounting
On DIN rod 35 mm
EMC
Protections
EN61326-1 2013