Learning Advanced Features
292
8.40
Press Regeneration Prevention (To evade control
operation in the status of regeneration during
press)
Press regeneration prevention is used during press operations to prevent braking during the
regeneration process. If motor regeneration occurs during a press operation, the motor
operation speed automatically goes up to avoid the regeneration zone.
Group Code Name
LCD Display
Parameter Setting Setting Range
Unit
ADV
73
Regeneration
evasion mode
RegenAvd Mode 000-111
001
Bit
74
Regeneration
evasion function
for press
selection
RegenAvd Sel
0
No
0
–
1
-
75
Press
regeneration
prevention
operation
voltage level
RegenAvd Level
350
200 V class: 300
–
400
V
700
400 V class: 600
–
800
76
Press
regeneration
prevention
compensation
frequency limit
CompFreq Limit 1.00
0
–
10.00
Hz
77
Press
regeneration
prevention P-
Gain
RegenAvd Pgain 50.0
0
–
100.0
%
78
Press
regeneration
prevention I gain
RegenAvd Igain 500
20
–
30,000
ms