Learning Advanced Features
Adv
anc
ed
Feat
ur
es
203
8.2.3
Jog Operation via Keypad Input
The jog operation is available using the keypad input as well.
The priorities for the frequency, acc/dec time, and terminal block input during an operation in
relation to other operating modes (Dwell, 3-wire, up/down, etc.) are identical to jog operations
using the terminal input.
Group Code Name
LCD Display
Parameter setting Setting Range
Unit
DRV
11
Jog frequency
JOG Frequency
10.00
0.5
–
Max Freq
Hz
12
Jog operation
acceleration time
JOG Acc Time
20.00
0.00
–
600.00
sec
13
Operation
deceleration time
JOG Dec Time
30.00
0.00
–
600.00
sec
The table below lists parameter settings for a forward jog operation using the keypad input.
MODE
Group
Code
LCD Display
Parameter Setting
Setting Range
Unit
CNF
-
42
Multi-Key Sel
1
JOG Key
-
-
PAR
DRV
06
Cmd Source
0
Keypad
0
–
5
sec
After setting CNF-42 to
“1
(JOG Key)
”
and DRV-06 (in PAR mode) to
“0
(Keypad)
”
, you can start
the jog operation using the keypad by pressing the [MULTI] key on the keypad.
Summary of Contents for SV-iS7 Series
Page 17: ......
Page 114: ...Peripheral Devices 97 Group 2 ...
Page 115: ...Peripheral Devices 98 Group 3 ...
Page 116: ...Peripheral Devices 99 Group 4 ...
Page 159: ...Basic Functions 142 Code Description V1 Quantizing ...
Page 465: ...Safety Funtion STO Safe Torque Off 448 14 2 1 Safety Function Wiring Diagram ...