Learning Advanced Features
202
Code
Description
DRV-12 JOG Acc Time
Sets the acceleration speed for a jog operation.
DRV-13 JOG Dec Time
Sets the deceleration speed for a jog operation.
If a signal is entered at the jog terminal while an Fx operation command is on, the operation
frequency changes to the jog frequency and the jog operation begins.
8.2.2
Jog Operation 2-Forward/Reverse Jog via Multi-function
Terminal
For jog operation 1, an operation command must be entered to start an operation, but while
using jog operation 2, a terminal that is set for a forward or reverse jog also starts an operation.
The priorities for the frequency, acc/dec time and terminal block input during operation in
relation to other operating modes (Dwell, 3-wire, up/down, etc.) are identical to jog operation 1.
If a different operation command is entered during a jog operation, it is ignored and the
operation maintains the jog frequency.
Group Code Name
LCD Display
Parameter setting Setting Range Unit
DRV
11
Jog frequency
JOG Frequency
10.00
0.5
–
Max Freq Hz
12
Jog operation
acceleration time
JOG Acc Time
20.00
0.00
–
600.00
sec
13
Operation
deceleration time
JOG Dec Time
30.00
0.00
–
600.00
sec
IN
65
–
75
Px terminal
configuration
Px Define
(Px: P1
–
P8
[optional: P9
–
P11])
46 FWD JOG
-
-
47 REV JOG
Summary of Contents for SV-iS7 Series
Page 17: ......
Page 114: ...Peripheral Devices 97 Group 2 ...
Page 115: ...Peripheral Devices 98 Group 3 ...
Page 116: ...Peripheral Devices 99 Group 4 ...
Page 159: ...Basic Functions 142 Code Description V1 Quantizing ...
Page 465: ...Safety Funtion STO Safe Torque Off 448 14 2 1 Safety Function Wiring Diagram ...