background image

LRX™ 

RAPTOR

 

www.lrx-lighting.com 

 

Check on line for the latest updates at www.lrx-lighting.com 

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 

 

 

 
 

 
 
 
 
 
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                  

Summary of Contents for RAPTOR

Page 1: ...LRX RAPTOR www lrx lighting com Check on line for the latest updates at www lrx lighting com SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 1 1 ...

Page 2: ...erall condition of fixture structure Ensure all covers are installed in good condition and Inspect all lamps retaining grills mounting hardware and Inspect lamp sockets contacts wires and Inspect gel frame receivers Inspect gel frame holders mounting hardware and Inspect Socapex cable input connectors and contacts Inspect data connectors and contacts Inspect condition of U ground plug wire strain ...

Page 3: ...ration a daily inspection and log are required For handling information see page eleven If using a power trolley with this fixture please refer to LRX Power Trolley manual THERE ARE NO USER SERVICEABLE PARTS IF YOU ARE UNSURE ABOUT ANYTHING SUSPEND USE OF THE PRODUCT Questions contact LRX LLC service representative at lrx lighting com and go to contact page For the latest version of this manual pl...

Page 4: ...t the light source When fixtures are mounted in close proximity to one another care must be taken so that output energy from one fixture is not directed at another fixture or electrical cabling FIXTURE ADDRESSING Fixture addressing is performed at the rear of the fixture hanger assembly The fixture can be programmed to operate in DMX mode or FIXTURE mode for use with the hand controller Because ea...

Page 5: ...ld until the display stops flashing to store that address It is important to note that the LRX fixture will not begin responding to a newly selected FIXTURE DMX address until it has been stored by pressing and holding the store round icon button If the display is flashing this is a warning that the displayed FIXTURE DMX address does not match the address that fixture is currently responding to Sav...

Page 6: ...LRX RAPTOR www lrx lighting com Check on line for the latest updates at www lrx lighting com SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 5 5 ...

Page 7: ... 127 ON N 11 lamp control unimplemented N 12 motor control MODE N 12 127 BUMP MODE N 12 127 FADER MODE N 13 reserved future use N 14 reserved future use N 15 reserved future use If MODE BUMP n 12 128 N 0 127 pan left N 1 127 pan right N 2 127 tilt up N 3 127 tilt down N 4 127 spot N 5 127 flood N 6 127 trolley left N 7 127 trolley right N 8 9 reserved future use If MODE FADER n 12 128 N 0 64 pan l...

Page 8: ...2 fixtures control of tilt up down pan left right and flood spot functions and will also shut off individual gel cooling fans or all gel cooling fans connected to that controller All switches act as momentary type When the Individual Gel Fan Stop switch is held the gel fan for the fixture indicated on the display stops When the All Gel Fans Stop switch is held all gel fans connected to that hand c...

Page 9: ... 60 Input Connector for lamps Socapex SL61 19 Contacts Model 419AR Quantity Three six lamps per connector one lamp per circuit Data DMX protocol Data connector XLR type five pin five wire Pin 1 ground Pin 2 Data negative Pin 3 Data positive Pin 4 12VDC negative Pin 5 12 VDC positive Physical Tilt Range one hundred degrees vertical Zero degrees to negative one hundred and twenty degrees Pan 340 deg...

Page 10: ...LRX RAPTOR www lrx lighting com Check on line for the latest updates at www lrx lighting com SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 9 9 ...

Page 11: ...der over the loosened thumb screws and lower into place Tighten thumb screws and install the four safety clips provided The outside gel slot must be used first as this will hold the two gel frame holders together No gel material is to be used on the side of the filter frame that has been slotted These slots will mate with bend returns on the outer most slot of the filter frame holder See illustrat...

Page 12: ...ture lifting handles provided as well as the yoke tubes If there are any concerns regarding handling please contact your supervisor Ensure hanger bolts are installed immediately after hanging before the ratchet straps are tensioned Ratchet straps must have a minimum of one and a half wraps around the ratchet drum at all times Removal of shipping case covers require two persons to lift Always use l...

Page 13: ...rtical Pan fixture so that it is pointed straight ahead Install onto shipping frame tighten hanger bolts and ratchet straps ensure there is a minimum of 1 5 wraps on the ratchet drum Secure gel frame holders using the Velcro straps provided in the shipping trays Place hand controller into Pelican case and place in tray Hang DMX cables on shipping stand Always store equipment in a dry location Ensu...

Page 14: ...regarding use and handling of their product This fixture has more than one power supply Disconnect all power supplies before installation or removal of the lamps Allow lamps to cool before removing Loosen the two screws that hold the lamp retaining ring then rotate ring to remove Prior to installing the lamp check lamp contacts and wire ends for signs of arcing or over heating If lamp contacts or ...

Page 15: ... the ratchet to ensure they remain tight Always use approved safety cables secured to a point capable of supporting the total weight of the load All power and data cables must have a strain relief attached When fixtures are mounted in close proximity to each other care must be taken so that output energy from one fixture is not directed at another fixture or electrical cabling Power trolleys must ...

Page 16: ...ting com SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 15 15 Load must be centered front to back as well as side to side Using two truss plates 1 2 X 3 per side a minimum of two structural members must be captured Fasten using X 4 bolts with washers lock washers and nuts four places ...

Page 17: ...all five wires and pins are required to operate hand controller Check hanger display for proper addressing and mode For use with hand controller the fixture display must show the F prefix not the three digit DMX channel and the display must not be flashing It is important to note that the LRX fixture will not begin responding to a newly selected FIXTURE DMX address until it has been stored by pres...

Page 18: ...ome disengaged Actuate drive function and listen for motor operation The tilt and pan drive assemblies use a slip clutch inline between the motor and drive gear as a protective measure this clutch will slip and make a clicking sound once each revolution when driven by the motor if the clutch has exceeded it preset limits If any of these conditions exist suspend use of the product and call for serv...

Page 19: ...erall condition of fixture structure Ensure all covers are installed in good condition and Inspect all lamps retaining grills mounting hardware and Inspect lamp sockets contacts wires and Inspect gel frame receivers Inspect gel frame holders mounting hardware and Inspect Socapex cable input connectors and contacts Inspect data connectors and contacts Inspect condition of U ground plug wire strain ...

Reviews: