CAUTION
Battery Error
INTERRUPT
High Input Volts
- No battery connected?
- Wrong battery polarity, bad contact?
- Defective battery?
- Wrong LiPo-cell quantity?
- Input voltage too low/switched off (<11.0V on DC input)
- Bad contact on input clamps?
ERROR-MESSAGES POSSIBLE CAUSES
INTERRUPT
Low Input Volts
- Input voltage too high (>15.0V on DC input)
The QUADRA-PRO 2 is protected against faults and operator errors by the Multi-Protection-System.
Faults/Errors are displayed on the LCD screen and some faults/errors may interrupt the charging process
to protect the charger and the battery.
The error messages are as follows:
troubleshooting
MENU
MENU
start
start
MENU
MENU
MENU
MENU
MENU
NiMH 5.0A 00m35s
08.58V 0048mAh
Done 50m03s
09.06V 4170mAh
P1 MENU
Settings
SET Charge
Current: 04.0A
SET Battery
Type: NiMH
start
SET Battery
Type: NiCd
SET Battery
Type: LiPo
SET Charge
D-Peak: 20mV
SET Charge
Trickle: Off
SET Discharge
Current: 1.0A
SET Discharge
Voltage: 5.4V
MENU
MENU
MENU
MENU
SET Charge
Current: 03.0A
MENU
SET Charge
LiPo Volt: 07.4V
MENU
MENU
DEC
INC
DEC
INC
SET Discharge
Current: 1.0A
SET Discharge
Voltage: 6.0V
MENU
MENU
MENU
DEC
INC
press „Menu“ button
EXPLANATION OF ICONS:
start
press „Start/Stop“ button
press „INC“ or „DEC“ button
automatically hops to next screen/function.
SET Battery
Type: LiFe
MENU
SET Charge
Current: 03.0A
MENU
SET Charge
LiFe Volt: 06.6V
MENU
DEC
INC
SET Discharge
Current: 1.0A
SET Discharge
Voltage: 5.2V
MENU
MENU
MENU
MENU
SET Charge
Current: 03.0A
SET Charge
D-Peak: 50mV
SET Charge
Trickle: Off
SET Discharge
Current: 1.0A
SET Discharge
Voltage: 5.4V
MENU
MENU
MENU
progrAmme struCture
INTERRUPT
Low Bal. Volts
INTERRUPT
High Bal. Volts
INTERRUPT
Open Balancer
- Cell voltage at balancer port too low?
Limits are: LiPo=2.75V, LiFe=2.0V, NiCd/NiMH=0.1V
- Cell voltage at balancer port too high?
Limits are: LiPo=4.3V, LiFe=3.9V, NiCd/NiMH=2.0V
- Balancing wire disconnected from balancing port during use?
Partial Charge Mode:
Never store your batteries completely empty as this will harm them and lower their performance. Due to this fact,
the QUADRA-PRO 2 features a „Partial charge“ mode. With this function, you can set a fixed capacity value and the battery will be partially
charged exactly to this amount.Thus you can always perfectly prepare your battery for storage, if you want to store them over a longer period
of time.
How to partially charge a battery: please follow the instructions under chapter „Programme Structure“.
We recommend to completely discharge the battery first and then put about half of the nominal capacity back into the battery. For example, a
battery with a nominal capacity of 4200mAh should be partially charged with 2100mAh.
Note:
NiMH batteries can be stored for about 1-2 months without problems using this method. LiPo/LiFePo batteries can be stored for about 6
months without problems. After this time period, you should check the battery and, if necessary, put some partial charge in again if you don´t
use it regularly.
Autostart Timer:
This handy feature lets you preselect when you want to start charging your battery with the QUADRA-PRO 2. The
Autostart Timer is adjustable from 0 - 99min. If you stay in the „Autostart Display“ for longer then 30sec without setting a value, the charging
process will start automatically.
Changing the charge current on the fly:
The charge current can be changed on the fly by pressing INC+ or DEC- without inter
-
rupting the charging process. This change is not stored. The next time you start charging, the QUADRA-PRO 2 takes the data settings of each
charge profile, stored under “Settings”.
PCS-4 (Peak Capacity System):
The voltage charge curve of NiMH cells may vary considerably at the start of charging due to cell
construction. Conventional chargers interpret this incorrectly as „delta peak reached“ and terminate the charging process (false peak). The QUA
-
DRA-PRO 2 has the LRP-exclusive PCS-4 which contains advanced algorithms to detect this phenomenon: This ensures reliable full charging.
PCS-4 allows the perfect full charge of all NiMH cell types by means of an adjustable delta peak and high-precision digital-filter detection of all
parameters throughout the entire charging process. The QUADRA-PRO 2 signals full charge and end of charge by an alert buzzer that sounds
for 3 minute.
Data View Function:
at the end of each process (charge, discharge or cycle) you can view additional data by pressing MODE button.
Also you can access DATA VIEW from initial screen by pressing MODE button, which allows you to view (press MENU again to hop through data):
DC input voltage / Battery voltage / Charge data from last process / Discharge data / Balancing Voltages from last process
speCiAl FeAtures
Inp13.7V 00m37s
08.59V 0051mAh
D-Peak: 10mV
Trickle: Off
Charge
Autostart:00min
Partial Charge
Capacity: 1.0Ah
P1 MENU
Charge
start
Balance
Conn. xS PACK
MENU
start
Disch1.0A 0029s
07.61V 0080mAh
Discharge
Voltage: 5.4V
P1 MENU
Discharge
Balance
Conn. xS PACK
Done Avg.07.396V
07.74V 3950mAh
Done 1422s
07.75V 3950mAh
Trickle 0.25A
09.06V 4170mAh
MENU
start
Disch1.0A 0012s
06.51V 0033mAh
Disch1.0A 05.4V
Charg 5.0A
P1 MENU
Cycling
Balance
Conn. xS PACK
Done Avg.07.383V
07.72V 4023mAh
Done 1448s
07.72V 4023mAh
Cyc 1.0A 0013s
06.52V 0035mAh
NiMH5.0A 00m40s
08.60V 0055mAh
Cyc 5.0A 00m42s
08.60V 0058mAh
Disch1.0A 0120s
07.58V 0333mAh
Cyc 1.0A 0121s
07.57V 0334mAh
MENU
start
Bal. 3.42 3.52V
3.50 3.32 3.45V
P1 MENU
Balance
Balance
Start .....
Bal.
Pack.V: 12.50V
Bal. 3.32 3.32V
3.32 3.32 3.32V
Done 3.32 3.32V
3.32 3.32 3.32V
number of cells which are recognised as connected to balancing
port are indicated (e.g. 2S, 3S, 4S or 5S).
„No Connection“ is displayed if there is no connector attached.
1
1
1
1
„Trickle“ screen is only available if
trickle is not set to „Off“
This screen is not available when
„LiPo“ or „LiFe“ cells are choosen.
Delay/
Pause
Delay/
Pause
0.1-5.0A
5-200mV
Off/0.25A
0.1-1.0A
0.9-16.0V
0.1-5.0A
5-200mV
Off/0.25A
0.1-1.0A
0.9-16.0V
0.1-5.0A
3.7/7.4/11.1/14.8/18.5V
0.1-1.0A
2.8-18.5V
0.1-5.0A
3.3/6.6/9.9/13.2/16.5V
0.1-1.0A
2.8-18.5V
DEC
INC
repAir proCeDures / limiteD wArrAnty
All products from LRP electronic GmbH (hereinafter called “LRP”) are manufactured according to the highest quality standards.
LRP guarantees this product to be free from defects in materials or workmanship for 90 days (non-european countris only) from
the original date of purchase verified by sales receipt. This limited warranty doesn’t cover defects, which are a result of misuse,
improper maintenance, outside interference or mechanical damage.
„This applies among other things on:
• Cut off/changed original input- and/or output-wires
• Mechanical damage of the case, electronic components or PCB
• Humidity/Water inside the case
• Soldered on the PCB“
• Charger disassembly by customer
• Any modification of the charger done by the customer
• Over temperature failures due to blocking the fan or the cooling slots
• Reverse polarity at DC output
To eliminate all other possibilities or improper handling, first check all other components in your model and the trouble shooting
guide, if available, before you send in this product for repair. If products are sent in for repair, which do operate perfectly, we have
to charge a service fee according to our pricelist.
With sending in this product, the customer has to advise LRP if the product should be repaired in either case. If there is neither
a warranty nor guarantee claim, the inspection of the product and the repairs, if necessary, in either case will be charged with
a fee at the customers expense according to our price list. A proof of purchase including date of purchase needs to be included.
Otherwise, no warranty can be granted. For quick repair- and return service, add your address and detailed description of the
malfunction.
If LRP no longer manufactures a returned defective product and we are unable to service it, we shall provide you with a product
that has at least the same value from one of the successor series.
The specifications like weight, size and others should be seen as guide values. Due to ongoing technical improvements, which are
done in the interest of the product, LRP does not take any responsibility for the accuracy of these specs.
With LRP 25-Years Warranty products, the warranty terms on the LRP 25-Years Warranty card do also apply. The legal warranty
claims, which arose originally when the product was purchased, shall remain unaffected.
LRP-Distributor-Service:
• Package your product carefully and include sales receipt and detailed description of malfunction.
• Send parcel to your national LRP distributor.
• Distributor repairs or exchanges the product.
• Shipment back to you usually by COD (cash on delivery), but this is subject to your national LRP distributor‘s general
policy.