LPR Pulsar Touch Competition User Manual Download Page 4

config

touchscreen calibration

useful accessories

troubleshooting

rePair Procedures / limited warranty

recommended charge currents

 

 P1 PROFILE NAME

    

 

       

     CONFIG 

 
 

   

 

 

 

SETUP 

 

 FACTORY DEFAULTS   X

 

 
 

Are you sure you       

    want to Reset? 

 
 

 

ok

 

 

 

FACTORY defaults 
 

INITIALIZATION... 
 

 

 ________ 

 

 

CALIBRATE OUTPUT   X  

 

 Voltage          _           

 0.000V          +1 

ok

 

 

 

 

 

NEXT

 

 

 

    

       

 
 
      

 

 

 

 

 

 

< Touch Screen > 
< CALIBRATION  >  

Min=0000, 0000 

Max=0000, 0000 

 

 

 

 

 

 

< Touch Screen > 
< CALIBRATION  >  

Min=0000, 0000 

Max=0000, 0000 

 

 

 

[ CHARGER RESET ] 

 

  

Please wait...

 

 

 

P1   CONFIG  [1/2] X

 

Button Sound :  On 

Finish Sound :15sec 
Finish Melody:   1 

 LCD Contrast :   10 

Temp Scale   :   

  

 

 

SET

 

 

 

 

 

NEXT

 

 

 P1   CONFIG  [2/2] X

 

*Factory Reset 

*Calibrate Output 
*Calibrate Balancer  
 

 

SET

 

 

 

 

 

NEXT

 

 

 

CALIBRATE BALANCER X

 

1s 0.000V         +1  

2s 0.000V         +1  

3s 0.000V         +1  

4s 0.000V         +1  

 

 

ok

 

 

 

 

 

!

    [ERROR]

      BALANCER

Cell Voltage 

to high

!

    [ERROR]

      INTERNAL

Calibration 

Data damaged

!

    [ERROR]

      BALANCER

Cell Voltage

 to low

!

          

[ERROR]

       INPUT

Input Failure

must be 11-15V

!

    [ERROR]

      INTERNAL

Temperature 

Overload

!

    [ERROR]

       SENSOR

Temperature Sen-

sor disconnected

!

    [ERROR]

       OUTPUT

Voltage to high

!

    [ERROR]

      BALANCER

Cells connected 

to different

!

    [ERROR]

      BATTERY

Temperature 

to low

!

    [ERROR]

       OUTPUT

Short Circuit

!

      [ERROR]

         OUTPUT

Battery connected 

with wrong polarity

!

    [ERROR]

       OUTPUT

Loss of 

connection

!

    [ERROR]

       OUTPUT

Voltage to low

!

    [ERROR]

       OUTPUT

No conection

!

    [ERROR]

      BATTERY

Temperature 

to high

All products from LRP electronic GmbH (hereinafter called “LRP”) are manufactured according to 

the highest quality standards. LRP guarantees this product to be free from defects in materials or 

workmanship for 90 days (non-european countris only) from the original date of purchase verified 

by sales receipt. This limited warranty doesn’t cover defects, which are a result of misuse, impro

-

per maintenance, outside interference or mechanical damage.
„This applies among other things on:

•  Cut off/changed original input- and/or output-wires

•  Mechanical damage of the case, electronic components or PCB

•  Humidity/Water inside the case

•  Soldered on the PCB“

•  Charger disassembly by customer

•  Any modification of the charger done by the customer

•  Over temperature failures due to blocking the fan or the cooling slots

•  Reverse polarity at DC output

To eliminate all other possibilities or improper handling, first check all other components in your 

model and the trouble shooting guide, if available, before you send in this product for repair. If 

products are sent in for repair, which do operate perfectly, we have to charge a service fee ac-

cording to our pricelist.

With sending in this product, the customer has to advise LRP if the product should be repaired 

in either case. If there is neither a warranty nor guarantee claim, the inspection of the product 

and the repairs, if necessary, in either case will be charged with a fee at the customers expense 

according to our price list. A proof of purchase including date of purchase needs to be included. 

Otherwise, no warranty can be granted. For quick repair- and return service, add your address and 

detailed description of the malfunction.

If LRP no longer manufactures a returned defective product and we are unable to service it, we 

shall provide you with a product that has at least the same value from one of the successor 

series.

The specifications like weight, size and others should be seen as guide values. Due to ongoing 

technical improvements, which are done in the interest of the product, LRP does not take any 

responsibility for the accuracy of these specs.
With LRP 25-Years Warranty products, the warranty terms on the LRP 25-Years Warranty card do 

also apply. The legal warranty claims, which arose originally when the product was purchased, 

shall remain unaffected.

LRP-Distributor-Service:  

  

•  Package your product carefully and include sales receipt and detailed description of 

malfunction.    

•  Send parcel to your national LRP distributor.    
•  Distributor repairs or exchanges the product.    
•  Shipment back to you usually by COD (cash on delivery), but this is subject to your 

national LRP distributor‘s general policy.

In „Config“ the 

Pulsar Touc

h can be customised to your likes (adj. finish sound, °C or °F, etc), reset the charger to our factory 

default setting plus it also allows you to calibrate the voltage readings of output jacket and balancer for maximum precision.

If you should ever recognise a big difference between the LCD display and your actual touch point, you may need to re-

calibrate the positioning of the touchscreen!

How to re-calibrate the touchscreen:

The 

Pulsar Touch 

is protected against faults and operator errors by the Multi-Protection-System. Faults/Errors are displayed on the LCD screen and they  

interrupt the active process to protect the unit and the battery. 

Error Messages:

The crossed-out wheeled bin means that within the European Union the product 

must be taken to seperate collection at the product end-of-life. Do not dispose of 

these products as unsorted municipal waste.

LRP offers a comprehensive line of accessories, as well as particular spare- and optional items. Here you find an overview, 

for a full picture please visit our website at www.lrp.cc:
  #43150 

Competition 14A Powersupply

  #65821 

Charge Wire Harness, LiPo 2S Hardcase

  #65822 

Charge Wire Harness, LiPo 2S Saddle Hardcase

 #65835 

4.0mm Silver plated connectors (10pcs)

  #65845 

LiPo Safe (Safety Bag, 23x30cm), 

  #81907 

3.3mm² Powerwire black (1.0m)

  #81908 

3.3mm² Powerwire blue (1.0m)

„On“ or „Off“

„Off“, „5sec“, „15sec“
1-5 (different melodies)
depending on light condition, contrast may be altered.
„°C“ or „°F“

Calibrate  voltage  at  output 

jacket.

All chargers come of course calibrated from the factory, but due to aging of 

components this calibration can slightly change over time.

Additionally the „Calibration“ may be a useful tool at races when LiPo voltage 

limit is checked and you can therefore adjust your charger to the multimeter 

used in technical inspection in the best way.

Calibrate voltage of each cells 

balancer.

Calibration process:

1. connect a battery to Pulsar Touch.
2. enter „Calibration Mode“.
3. connect a separate voltmeter to the con

-

nection you would like to calibrate.

4. compare reading in dispay with reading 

on your voltmeter.

5. adjust voltage on display using up/down 

arrow keys.

6. done when vol charger indicate 

the same value. The press „ok“.

Reset‘s your profile settings and profile names to our factory 

defaults, please see section „Factory Defaults“ for values.

1. input voltage too low (<11.0V) 

or too high  (>15.0V)?

2. powersupplies current to low 

for selected charge current?

3. contact/wiring problem?

1. no battery connected?
2. bad contact on output?
3. defective battery?

1. wrong battery connection!

1. contact/wiring problem?
2. defective battery?

1. contact/wiring problem?
2. defective battery?

1. wrong setting for battery you 

connected?

1. wrong setting for battery you 

connected?

2. contact/wiring problem?
3. defective battery?

1.charger to hot, let charger cool 

down!

1. discharge level of cells within 

pack to different?

2. bad contact at balancer?
3. defective battery?

1. wrong setting for battery you 

connected?

2. contact/wiring problem?
3. defective battery?

1. wrong setting for battery you 

connected?

Caution:

 only if optional tempe-

rature sensor is connected! 

1. battery to cold?
2. contact/wiring problem?

Caution:

 only if optional tempe-

rature sensor is connected! 

1. battery to warm?
2. contact/wiring problem?

Caution:

 only if optional tempe-

rature sensor is connected! 

1. contact/wiring problem?
2. sensor defective?

Internal error, re-start your char

-

ger and if needed reset to factory 

defaults  and  calibrate  output/

balancer again

15A Fuse:

 If the display is dark at power-up, you should check 

for correct wiring first and then should also check the input fuse

input fuse for protection, only replace with another 

15A fuse (blue coloured housing)  and no other types 

as these would not offer protection or correct function!

Important:

 always follow the battery manufacturers recommendations first, our own recommen

-

dation should only be seen as a guideline for the most common battery packs!

Battery 

Type

Chg 

Mode

Pack 

Volt

Current DPeak Trickle

LiPo 2S * 40-50C * 1/10 * ~5500mAh

LiPo

7.4V / 2S

10.0A

--

--

LiPo 1S * 40-50C * 1/12 * ~5200mAh

LiPo

3.7V / 1S

8.0A

--

--

LiPo 2S * Low C * TX Pack * 2500mAh

LiPo

7.4V / 2S

2.5A

--

--

LiPo 3S * Low C * TX Pack * ~2500mAh

LiPo

11.1V / 3S

2.5A

--

--

LiFe 2S * 30-50C * 1/10 * ~4500mAh

LiFe

6.6V / 2S

8.0A

--

--

LiPo 2S * Low C * RX-Pack * ~2000mAh

LiPo

7.4V / 2S

2.0A

--

--

LiFe 2S * Low C * RX-Pack * ~1500mAh

LiFe

6.6V / 2S

1.5A

--

--

LiPo 2S * 20-35C * 1/10 Sub-C size

LiPo

7.4V / 2S

5.0A

--

--

LiPo 3S * 20-35C * 1/10 Sub-C size

LiPo

11.1V / 2S

5.0A

--

--

NiMH 1/10 Sportpack (2000-3800mAh)

Linear

--

4.0A

20mV

Off

NiMH 1/10 Sportpack (>3800mAh)

Linear

--

5.0A

20mV

Off

NiMH AA/Mignon TX-Pack (~2500mAh)

Linear

--

1.0A

30mV

Off

NiMH RX Pack (~1500mAh)

Linear

--

1.5A

15mV

Off

For  any  other  pack,  make  sure  you  select  correct  settings  („Chg  Mode“  and  „Pack  Volt“)  and 

charge with 1C* charge rate.
Leave  the  settings  „Cut  Temp“  (40°C  for  LiPo/LiFePo  and  55°C  for  NiMH)  and  „Safety  Timer“ 

untouched.

* C=Nominal capacity of the battery. E.g. with a nominal capacity of 4000mAh (4.0Ah), the battery can be 

charged with a max. current of 4.0A at 1C.

1.  with no power connected to the charger, keep the touchscreen pressed and 

then connect the power to the charger.

2.  keep the screen pressed, the charger will beep to indicate the charger is con

-

nected to power first and if you keep the screen pressed it will make short 

beeps. At this time, detach your hand from the screen.

3.  an arrow will now be displayed in the upper left corner, precisely press the end 

point of the arrow for 2sec. 

4.  an arrow will now be displayed in the lower right corner, precisely press the 

end point of the arrow for 2sec. 

5.  the new touchscreen calibration is stored and you are done.

Reviews: