MAINTENANCE
7
7
>
MAINTENANCE
Don’t mobilize the motorized flap manually.
≥
A T T E N T I O N
TREA
TMENT HEADS
TREA
TMENT HEADS
Fig 1
Fig 2
Fig 3
Fig 4
THE TR30 HEAD
1. Remove the sealing flaps as showed in the pictures below (fig. 1).
2. Thoroughly rub for at least one minute with the wipes as describe here below:
a) The flaps and their housing (fig 2 & 3).
b) The casing on both sides of the rollers (turn the head over, rotate the rollers
manually to clean the entire surface) (fig. 4).
3. Reattach the sealing flaps
4. Maintain the storage drawer using LPG wipes, then place the head in it.
FIG. 3
FIG. 1
FIG. 2
ROTATION 90°
ROTATION 90°
FIG. 4
ERGOLIFT HEAD AND ERGOLIFT CHAMBERS
For reasons of hygiene, the maintenace of the care heads should be performed after each
use, using antiseptic wipes impregnated with a bactericidal and fungicidal solution.
Special attention must be given to the cleanliness of the parts that are in contact with
the client.
1. Disconnect the chamber from the Ergolift care head. (fig. 1)
.
2. Remove the flap thanks to the dedicated tool. (fig. 2).
3. Thoroughly rub the Ergolift chamber, the flap and the tool for at least one minute
with the wipes as describe here below. (fig. 3).
4. Put the flap back in the Ergolift chamber by following the same steps in the reverse
order (fig. 4).
REMOVAL TOOLS