If during this operation water outflow looks yellowish, is mainly due to the preservatives in ion exchange
resins, just let water circulate until flow becomes a normal appearance.
· The display indicates which bottle valve is then in service.
Allow a time of approximately one minute at each step of the regeneration.
Press the "MENU / CONFIRMATION" key (*) twice to force manual regeneration. Press once during the rege-
neration to skip to the next step.
Startup and regulating water hardness:
Once the setup and programming cycles, it is time to adjust the residual water hardness (for descaling)
through the bypass formed by the keys that were installed in the pipes.
It is recommend adding an additional key for this setting, which is
connected in series with the key B of the previous figure, and after
adjusting the handle is removed to prevent tampering by anyone
other, keeping the B key open during normal use softener.
Note:
· For human consumption it is recommended an adjustment of
7-8 ºF.
· If you require for industrial purposes have a hardness of 0ºF
close the B key and let all the water is treated.
*