Sending unit mounting plate configurations vary. When connecting the
EP-15, you will need whatever tools and supplies that will work with your
sending unit's specific design. Recommended tools include: pliers. If you
need to route the smart module or cable connector through a bulkhead,
you will need a drill and a 7/8" (22 mm) drill bit.

Supplies are not included, unless otherwise indicated. The EP-15's two
lead wires are pre-stripped. We recommend using marine-grade crimp-on
connectors that will fit your sending unit's electrical connections.

Installation

This instruction sheet assumes the mounting bracket is connected to
the fluid level arm (or potentiometer) and is already installed in the
tank. The EP-15 wires — red (positive) and black (negative) — will
connect to the sending unit's mounting bracket, on top of the tank.

Tip:

The EP-15 is designed to be the only device receiving signals from
the sending unit. If the EP-15 is replacing a previous gauge, make
sure you remove all the old gauge wires before you begin. If this is a
replacement, note which connection is positive before disconnecting
the old wires.

Caution:

Do NOT connect the sensor's blue locking collar connector to the
network until you have finished connecting the red and black
leads to the sending unit. This reduces the risk of a stray spark
when working around fuel tanks.

Your first step is to attach marine-grade crimp-on connectors to both
the red lead (+) and the black (–) lead.

Attach appropriate connectors to wire leads.

Summary of Contents for EP-15

Page 1: ...nstallation instructions before proceeding You should decide where to install all components before drilling any holes in your vessel Some sonar or GPS units may require a software upgrade to display...

Page 2: ...er Lowrance Electronic Probe EP sensors is designed only for use with a NMEA 2000 Network It must be connected to a NMEA 2000 network or it will not function Tools and Supplies Your EP sensor packs wi...

Page 3: ...or potentiometer and is already installed in the tank The EP 15 wires red positive and black negative will connect to the sending unit s mounting bracket on top of the tank Tip The EP 15 is designed...

Page 4: ...o use Connecting to a NMEA 2000 Network A network bus is an installed and operational network cable backbone running the length of your boat already connected to a power supply and properly terminated...

Page 5: ...already exists This connection could be at the end of the network between a T connector and a terminator between two T connectors between a T connector and a backbone extension cable or between two ex...

Page 6: ...device The soft T connector shown above with a hard T connector is another option for connecting devices in a NMEA 2000 network The soft T works the same as a hard T The soft T is used to install a ne...

Page 7: ...ENT OR REFUND AS JUST DESCRIBED IS THE EXCLUSIVE REMEDY AVAILABLE TO YOU AGAINST US FOR ANY DEFECT MALFUNCTION OR NON CONFORMITY CONCERNING THE PRODUCT OR FOR ANY LOSS OR DAMAGE RESULTING FROM ANY OTH...

Page 8: ...or sonar and GPS products manufactured by Lowrance Electronics and Eagle Electronics To order Lowrance or Eagle accessories please contact 1 Your local marine dealer or consumer electronics store To l...

Reviews: