All Lowrance NMEA 2000 capable devices are NMEA 2000 certified or
certification is pending. See our web site for the latest product status
information.

The EP-10 consists of a blue female locking cable connector and the
sensor module. The sensor module contains a turbine to measure fuel
flow and electronics which convert flow data to the NMEA 2000 data
format. The cable length from the connector to the smart module is 10
feet. The EP-10 sensor is designed to work with 

gasoline

 engines only.

This sensor has been optimized to measure flow rates between 0.6 to 45
gallons (U.S.) per hour, but it will operate at flow rates outside that
range. The sensor will add 0.5 PSI of back pressure on the fuel system
with a flow rate of 20 gallons per hour. At the rate of 40 gallons per
hour the back pressure will be 1 PSI.

The EP-10, like other Lowrance Electronic Probe (EP) sensors, is
designed only for use with a NMEA 2000 Network. It 

must

 be

connected to a NMEA 2000 network or it 

will not

 function.

Tools and Supplies

Your EP-10 sensor comes with a T connector. The T connector is needed
to attach the sensor to a LowranceNET NMEA 2000 network. If you are
connecting to an existing LowranceNET network, those are all the
electronic components you need. If this is the first sensor you are
connecting, you also will need a one-time purchase of a LowranceNET
Node Kit.

LowranceNET Node Kit for a NMEA 2000 network. Includes a 2 foot

extension cable, T connector, 120-ohm male terminator and 120-ohm

female terminator.

For complete instructions on setting up a new NMEA 2000 network or
expanding an existing one refer to the "

Setup and Installation of NMEA

2000 Networks, General Information

" document (part number 988-

Summary of Contents for EP-10

Page 1: ...d all of the installation instructions before proceeding You should decide where to install all components before drilling any holes in your vessel Some sonar or GPS units may require a software upgra...

Page 2: ...the rate of 40 gallons per hour the back pressure will be 1 PSI The EP 10 like other Lowrance Electronic Probe EP sensors is designed only for use with a NMEA 2000 Network It must be connected to a N...

Page 3: ...Installation Install one EP 10 sensor per engine If you have multiple tanks place the sensor after any Y or T in the line feeding the engine The sensor should be installed vertically and as close as...

Page 4: ...you to remove a clogged EP 10 fuel sensor or fuel filter and restore engine operation if the fuel filter fails It is strongly recommend that you inspect your entire fuel system at regular intervals S...

Page 5: ...twork can share information Connections found in the middle of the bus will have one or more of these T shaped connectors with the backbone cables plugged into both sides Connections at the end of a n...

Page 6: ...u to add a device The soft T connector shown above with a hard T connector is another option for connecting devices in a NMEA 2000 network The soft T works the same as a hard T The soft T is used to i...

Page 7: ...ENT OR REFUND AS JUST DESCRIBED IS THE EXCLUSIVE REMEDY AVAILABLE TO YOU AGAINST US FOR ANY DEFECT MALFUNCTION OR NON CONFORMITY CONCERNING THE PRODUCT OR FOR ANY LOSS OR DAMAGE RESULTING FROM ANY OTH...

Page 8: ...or sonar and GPS products manufactured by Lowrance Electronics and Eagle Electronics To order Lowrance or Eagle accessories please contact 1 Your local marine dealer or consumer electronics store To l...

Reviews: