Lowell SEQ-4A Manual Download Page 2

Lowell strives to provide accurate information while reserving the right to change specifications and/or improve manufacturing methods without prior notification.  
©2022 Lowell Manufacturing Co., 100 Integram Dr., Pacific MO 63069 / tel. 800.325.9660 / www.lowellmfg.com 

Spec 2216

Model SEQ-4A  Rev. 09-20-22 | pg. 2/3

INTERNAL USE 

ONL

Y:

 PN 24188

INPUT CONNECTION OPTIONS:  

OUTPUT CONNECTION OPTIONS:  

V+

Sw

ON Ind.

OFF Ind.

V+

Sw

ON Ind.

OFF Ind.

Connect to

MOMENTARY

Remote Switches

+24V

Com

N.O.

N.C.

Model MSM2

Connect

to RPC

See Spec/Install sheet

for application details

Off

On

Connect to any physical switch or 

control system that will provide a 

maintained

 dry contact closure

Dry Contact Control

Switch

Common

24VDC Output

200mA max

Trigger Input

5v – 24v AC or DC

Connect to any device or control system 

that will provide a 

maintained

 voltage 

between 5 and 24 volts AC or DC.

If DC, observe polarity:

Common=Neg, Trigger Input=Pos.

Voltage Control

Switch

Common

24VDC Output

200mA max

Trigger Input

5v – 24v AC or DC

Any Lowell RPSW or RPSB series 

maintained

 contact

remote switch model (rocker or keylock)

On

On

Rocker 

Switch

Key 

Switch

Switch

(Sw)

Com

+24V

2.2K 1/2W Re

si

st

or

Schematic

Grn LED

Single Remote Switch Control

Switch

Common

24VDC Output

200mA max

Trigger Input

5v – 24v AC or DC

Switch

Common

24VDC Output

200mA max

Trigger Input

5v – 24v AC or DC

Key 

Switch

On

Off

(Connect 

to NO)

Grn LED

2.

2K 1/

2W

Re

si

st

or

V+

Switch

(Sw)

ON

 Ind.

Red LED

OFF

 Ind.

Schematic

Any Lowell RPSW2-M or RPSB2-M series 

momentary

 

contact remote switch model (rocker or keylock)

Max. 6 switches

Multiple Remote Switch Control

Connect to 

either terminal

MSM2 Momentary Switch Module

SEQ-4A

SEQ-4A

SEQ-4A

SEQ-4A

Wire requirements:

Any generic cable, shielding not needed

Maximum distance between devices:

22ga wire: 1 mile

18ga wire: 3 miles

2 cond.

2 cond.

3 cond.

3 cond.

4 cond.

Rocker 

Switch

On

Off

Norm

Test

Ac

tiva

te

d

Po

we

r

In

pu

t 5v-2

4v

AC

 or

 DC

+2

4V

DC 

Ou

t

Co

mm

on

Sw

itch

G

G

Su

rg

Pr

ot

ec

tion

 Ac

tive

W

hen

 Li

t (-

mo

de

ls 

on

ly

)

LLoow

weellll

RPC Series

Remote Power Control Unit

R

G

R

Norm

Test

Pwr

Activated

Sw

itch

Co

mm

on

24

VD

Ou

tp

ut

20

0mA 

ma

x

Tr

igg

er

 In

pu

t

5v – 

24

AC

 or

 DC

No

rma

lly 

Cl

os

ed

No

rma

lly 

Cl

os

ed

No

rma

lly 

Op

en

No

rma

lly 

Op

en

Co

mmo

n

Co

mmo

n

RPC unit

(any model)

RY-2A or RY-4A Relay Module

To additional RPCs 

and/or relay modules

Step 1 connections shown

Steps 2, 3, and 4 connections are identical.

NOTE:

Any combination of RPC series models 

and/or RY series models may be 

connected to each sequencer step

Maximum 75 units per sequence step.

Wire requirements:

Any generic cable, shielding not needed

Maximum distance between sequencer and RPCs / relays:

22ga wire: 1 mile

18ga wire: 3 miles

NOTE: Maintain polarity

(switch to switch, com to com)

2 cond.

Delay Settings

ON

Approx. 5 sec. 

between steps

20 seconds total

ON

Approx. 2½ sec. 

between steps

10 seconds total

ON

Approx. 8 sec. 

between steps

32 seconds total

Approx. 12 sec. 

between steps

48 seconds total

ON

Reviews: