Technical Specifications
High-efficiency, shaftless spherical motor with ECM technology
Rated voltage
200-240 V
Frequency
50/60 Hz
Power consumption
2 … 27 W
Ingress Protection
Insulation class
Protection class
IP 44 , IP 42 with timer
155 (F)
I
Max. system pressure
1 MPa (10 bar)
Max. system temperature
65 °C
Min. ambient temperature
Not freezing/ non-condensing
5.
Pump Curve (see figure 2)
6.
Installation Sequence (see figure 3)
When using versions with pump housing 70, use the
LOWARA RV ½“ check valve. This prevents water from
flowing through the pump backwards when the faucet is
opened, thus causing damage. When using valves other than
RV ½“, pay attention to appropriate closing pressure. Install
the RV ½“ check valve in the direction of flow, so that the
arrows on the pump housing and on the check valve point in
the same direction.
We recommend that you install a ball shut-off valve before the
pump so the pump can be replaced at a later time without
completely draining the system.
Pumps with housings #10 and #94 already contain an
integrated check valve and a ball shut-off valve in the pump
housings. (The check valve opens and closes automatically;
when the handle of the ball shut-off valve is perpendicular to
the pipe direction, the valve is closed).
Description for figure 3:
1 - Water heater
2 - Check valve
3 - Ball shut-off valve
4 - Circulation pump type ecocirc PRO
7.
Installation
The pump may not be installed in areas where there is a danger of
explosion
The pump may not be used to pump flammable, or explosive liquids.
WARNING