[1]

- Zone Selector Switches

Selects zone for monitoring.  Press switch of desired zone to listen to live 

monitored audio. Pressing any switch also provides a switch closure for 
activating a camera, etc. (100mA max) 

[2]

- Filter-OUT Indicator

Lights (green) when audio filter is not in use.  Indicates power is “ON”.

[3]

- Filter-IN Indicator 

Lights (amber) when Filter Switch

[6]

 is pressed to “ON” position.

[4] 

- VCR-IN Indicator 

Lights (yellow) when VCR Switch

[7]

 is pressed to “ON” position.

[5] 

- Overload Indicator 

Current overload indicator.  Lights (red) when power short circuit occurs.

[6]

 - Filter Switch

Used only when audio playback is from a 12 or 24 hr. time lapse 
recorder.  Press Filter Switch[6] to illuminate red LED for 12/24 hour 
mode.  This enhances the quality of recorded audio playback.  If 
playback is from a DVR, filter switch is not used and should be in the 
“OUT” position.  If no recording device is used, then filter switch must be 
in the “OUT” position.  Otherwise live audio will be muted.  The green 
LED illuminates when filter switch is in the “OUT” position.

[7]

- VCR Switch

Press switch to “ON” (or “IN”)  position after connecting DVR/VCR to unit.  

(When switch is “OUT”, audio bypasses the DVR/VCR and is not 
recorded.  When switch is “IN”, audio is sent in for recording and 
playback.  Switch must always be “IN” whenever a recorder is 
connected. 

[8]

- Talkback switch

Press to talk to remote speakers.  Select a zone by pressing any Zone 

Selector Switch

[1]

 to talk to desired zone.  A built-in Talk back 

Microphone

[10] 

is located above the Headphone Jack

[11].

[9] 

- Power-Volume Control Knob

Rotating knob clockwise turns on power to the unit as indicated by the 

filter-OUT indicator

[2]

.  Green LED will illuminate.  Rotating clockwise 

also increases loudness of monitored audio from the Monitor 
Speaker

[13]

.

[10] - Talkback Microphone

Built-in microphone for talkback.

[11] - Headphone Jack

Used for private listening.  Any 3.5mm stereo headphone with 8 to 600

W

 

impedance may be used.  Speaker is muted when headphone is used.

[12] - Talkback Control Knob

Rotate knob clockwise to increase the loudness of talkback output; 

counterclockwise to decrease.

[13] - Monitor Speaker

Delivers audio through speaker.  Muted when a headphone is  plugged 

into the Headphone Jack

[11]

.

(not used with DVR’s)

(includes DVR’s)

(includes DVR’s)

MIC

POWER-VOLUME

OFF

MAX

TALKBACK LEVEL

OFF

MAX

SIXTEEN ZONE AUDIO SURVEILLANCE w/ talkback

AP-16TB

MADE IN USA

ZONES

1

2

3

5

6

7

8

4

PRESS

&

TALK

HEADPHONES

9

10

11

13

14

15

16

12

FILTER

VCR

[1]

[2]

[3]

[4]

[5]

[6] [7]

[8]

[9]

[10]

[11]

[12]

Fig. 1 AP-16TB 

Front Panel

[13]

INSTALLATION AND OPERATING INSTRUCTIONS

Page 2 of 8

LOUROE  ELECTRONICS    6 9 5 5   VA L J E A N   AVENUE,  VAN  NUYS,  CA  91406

TEL  (818)  994-6498

FAX 

994-6458

website: www.louroe.com                          e-mail: [email protected]

   

   

(818)

®

Ap_16tb_rm_inst_3/15

Summary of Contents for AP-16TB-RM

Page 1: ... 0dB 600W AD 3 24Vdc 1 5A power supply for powering both the unit and the remote speaker microrophones INTRODUCTION The AP 16TB RM is a sixteen zone rack mounted audio base station with 2 way talk listen capabilities It contains a built in microphone and speaker for two way audio communication to the remote station Unit has volume adjustments for both talk and listen Zone audio can be activated by...

Page 2: ...t always be IN whenever a recorder is connected 8 Talkback switch Press to talk to remote speakers Select a zone by pressing any Zone Selector Switch 1 to talk to desired zone A built in Talk back Microphone 10 is located above the Headphone Jack 11 9 Power Volume Control Knob Rotating knob clockwise turns on power to the unit as indicated by the filter OUT indicator 2 Green LED will illuminate Ro...

Page 3: ...ceed 1000 ft 20 DC IN Jack power Accepts 24 Vdc from external power supply AC adapter included Fig 2 Rear of AP 16TB 14 19 15 17 16 20 18 A B C 1 ZONES 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 SP 1A 24Vdc 2A 3A 4A 5A 6A 7A 8A 9A 10A 11A 12A 13A 14A 15A 16A G A B C SP G A B C SP G A B C SP G A B C SP G A B C SP G A B C SP G A B C SP G A B C SP G A B C SP G A B C SP G A B C SP G A B C SP G A B C SP G A ...

Page 4: ... recorder is used DVR VCR etc connect Audio OUT Jack 15 to recorder s Audio IN Jack with an RCA cable not supplied 7 Connect Audio IN Jack 17 to recorder s Audio Out Jack 8 Plug AC Adapter supplied to DC IN Jack 20 NOTE If AP 16TB RM is to be used as a one way listen only system no talkback any Louroe Verifact Microphone can be used Make microphone connections as described above see step 1 Disrega...

Page 5: ...o 5 Repeat steps 3 and 4 for the other zones 6 When a 24 hour VCR is connected to the unit press VCR Switch 7 VCR IN Indicator 4 will light yellow Start recording live audio It is not necessary to use VCR switch if recording into a DVR The VCR Switch 7 must be in the OUT position when a recorder is not connected to the unit Otherwise live audio will be muted 7 Recorded audio can be played back thr...

Page 6: ...LLATION AND OPERATING INSTRUCTIONS Page 6 of 8 LOUROE ELECTRONICS 6 9 5 5 VA L J E A N AVENUE VAN NUYS CA 91406 TEL 818 994 6498 FAX 994 6458 website www louroe com e mail sales louroe com 818 Ap_16tb_rm_inst_3 15 ...

Page 7: ...LECTRONICS warrants that at the time of shipment products manufactured by LOUROE ELECTRONICS to be free of defects in material and workmanship Should a defect appear within one year 12 months from date of shipment LOUROE ELECTRONICS will at its sole discretion repair or replace the defective equipment This equipment shall not be accepted for repair or return without prior notification by LOUROE EL...

Page 8: ...E INSTALLATION AND OPERATING INSTRUCTIONS Page 8 of 8 LOUROE ELECTRONICS 6 9 5 5 VA L J E A N AVENUE VAN NUYS CA 91406 TEL 818 994 6498 FAX 994 6458 website www louroe com e mail sales louroe com 818 Ap_16tb_rm_inst_3 15 ...

Reviews: