[6] -  Filter Switch

Normally used when playing back audio from a Time Lapse 
recorder.  This function is no longer available on this product

.

[7] -   DVR/VCR-IN Switch

Press to connect DVR/VCR into the unit.  Depressing switch 

bypasses the DVR/VCR even if it is connected physically to the 
back of the unit.  This eliminates the need to disconnect the 
DVR/VCR when not in use.

[8] -  Power-Volume Control Knob

Rotating knob clockwise turns on power to the unit, as indicated 

by the Filter-OUT Indicator

[2]. 

Rotating further clockwise 

increases the volume of the monitored audio produced through 
the Monitor Speaker

[10]

.

[9] -  Headphone Jack (3.5mm stereo)

Used for private listening.  Any monaural headset with 8 to 600

  

impedance maybe used.  Mutes the speaker output when in use.

   

DESCRIPTION AND FUNCTION OF PARTS

[1] -  Zone Selector Switches

Selects zone for monitoring.  Press switch of desired zone to 

listen to live audio.  Pressing more that one switch is possible 
when it is necessary to monitor more than one zone at a time, 
but audio may be difficult to understand if there is audio activity 
at several zones.

[2] - Filter-OUT Indicator

Lights (green) when audio filter is not in use.  Indicates power is 

“ON”.

[3] -  Filter-IN Indicator

Lights (red) when Filter Switch

[6]

 is pushed in to “ON” position.

[4] -  DVR/VCR-IN Indicator

Lights (yellow) when DVR/VCR switch

[7] 

is pushed in to “ON”.

[5] -  Overload Indicator

Lights (red) when a short or overcurrent in the power supply 

occurs.   If this occurs, turn OFF the Power-Volume Knob

[8] 

and 

check wiring connections (see troubleshooting, pg7).

Fig. 1 Front of AP-8

EIGHT ZONE A

UDIO SURVEILL

ANCE

MADE IN US

A

PHON

ES

1

2

3

4

5

6

7

8

ZONE

S

AP

-8

OFF

MAX

POWE

R-VOL

UME

VCR I

N

FILTE

R

PRES

S

PLAYB

ACK

FOR

OUT
IN

OVER

LOAD

3

4

5

6

1

2

7

8

9

Fig. 1 Front view of AP-8

AP-2 and AP-4 have the
same features except
for the number of Zones 

    

   

INSTALLATION AND OPERATING INSTRUCTIONS

Page 2 of 8

LOUROE  ELECTRONICS    6 9 5 5   VA L J E A N   AVENUE,  VAN  NUYS,  CA  91406

TEL  (818)  994-6498

FAX 

994-6458

website: www.louroe.com                          e-mail: [email protected]

   

   

(818)

®

ap_2_4_8_inst_5/11

Summary of Contents for AP-2

Page 1: ... Microphones and has four line level audio outputs All models contain a built in speaker for producing live audio and audio playback from a DVR In addition each model contains a selectable RCA audio output for interfacing with a DVR with only one audio input or with a VCR Zone selection is by pushbutton All Louroe microphones are compatible with the AP 2 AP 4 and AP 8 AP 2 AP 4 AP 8 AUDIO MONITORI...

Page 2: ... one switch is possible when it is necessary to monitor more than one zone at a time but audio may be difficult to understand if there is audio activity at several zones 2 Filter OUT Indicator Lights green when audio filter is not in use Indicates power is ON 3 Filter IN Indicator Lights red when Filter Switch 6 is pushed in to ON position 4 DVR VCR IN Indicator Lights yellow when DVR VCR switch 7...

Page 3: ...crophones 13 Audio Out Jack RCA Provides audio to DVR VCR for recording or to other audio devices accepting line level input 14 Audio In Jack RCA Receives audio playback from DVR VCR etc and is broadcast through the built in speaker 10 15 Mic Output Jack Used for connection to a DVR with multiple audio inputs or to a soundcard module for audio recording May also be used for paralleling to a second...

Page 4: ...o a DVR with one audio input 1 Connect an RCA cable to the Audio Out jack 13 of AP 2 AP 4 or AP 8 and connect other end to Audio In or line in of VCR DVR 2 To record press the Zone Selector Switch 1 located on front panel of base station for the audio zone to be recorded 3 For audio playback connect another RCA cable from Audio Out or line out of VCR DVR to Audio In 14 of AP 2 AP 4 AP 8 4 Press in...

Page 5: ... C A B C A B C A B C A B C A B C A B C A B C BACKSIDE OF VERIFACT A MICROPHONE L N 2 Conductor shielded cable 22 gauge with a 24 gauge drain wire West Penn 452 Belden 8451 or equivalent WIRING REQUIREMENTS 12 Vdc Power Supply ZONES SELECTABLE AUDIO OUTPUT Used only if recording device has only one Audio Input Used for Audio Playback from recorder Red A Black B Bare C Bare C Black B Red A Red A Bla...

Page 6: ...s connected to Mic Input 3 Pin Terminal Block 12 for zone 1 at the rear of the unit With a DC voltmeter check that 12 Vdc is present at terminals A and C If voltage is not present unit has defective regulator If voltage is present check to assure that wires are connected properly to the right terminals Otherwise microphone is defective Call factory for assistance 3 Repeat step 2 for the remainder ...

Page 7: ...oss terminal A and C A positive C ground of the Mic 3 Pin Terminal Block 12 It should read 12V The microphone requires 12Vdc to work 1 Check connections to the microphone b Remove the wire connected to the B terminal of the Mic 3 Pin Terminal Block Using an AC meter set to lowest voltage range check the presence of audio from the microphone Place the meter leads between wire removed positive and t...

Page 8: ...at the time of shipment products manufactured by LOUROE ELECTRONICS to be free of defects in material and workmanship Should a defect appear within one year 12 months from date of shipment LOUROE ELECTRONICS will at its sole discretion repair or replace the defective equipment This equipment shall not be accepted for repair or return without prior notification by LOUROE ELECTRONICS This warranty d...

Reviews: