3 - Initial Setup

Page 6

3.1 Selecting Channel

An indicator arrow at the bottom of the display points to the selected channel.
Press the center arrow button to select channel 

1 thru Total

 the 5 channels can

be used for 5 attachments or 5 different products. If only one attachment is used
select channel 1.

Center Button used to 

Select Channel 1-Total

3.2 Check/Change Display Readout

The Weighlog 100 can be set to read Tons "Eur" setting or lbs "USA" setting. The
default setting is tons. If lbs readout is desired follow the steps shown below.

Use the center arrow button and scroll to the "Total" channel

Press and hold the "Cal" button

to display weight readout.

To change weight readout.

Hold the "Cal" button and tap

the Center arrow button.

Summary of Contents for Weighlog 100

Page 1: ...Weighlog 100 Onboard Weighing System User Guide Calibration and Operation Issue Date 1 2007 Loup Electronics...

Page 2: ......

Page 3: ...l Support PLEASE CONTACT YOUR NEAREST DISTRIBUTOR If unknown Contact Loup Electronics 2960 North 38th Street Lincoln NE 68504 Phone 402 464 7131 Fax 402 464 7104 Toll Free 877 489 5687 Copyright Loup...

Page 4: ...3 1 Dynamic Weighing 7 3 3 2 Static Weighing 7 3 4 Check Change Weighing Modes 7 4 Check Set Zero Weight 8 4 1 Check Zero Weight 8 4 2 Set Zero Weight 9 5 Calibration 10 5 1 Weight Calibration 10 5 2...

Page 5: ...total of the channel being used and will also be added to the total channel which accumulates weight from all of the 5 channels The instrument has an illuminated 4 digit LCD display 3 front panel swit...

Page 6: ...strument can display up to 9990 tons or 99 990 lbs depending on mode selected When set to the USA or lbs setting the display will read up to 9990 lbs rounded to the nearest 10 lbs Above this weight re...

Page 7: ...lack of lubrication to grease points can have adverse effects on weighing accuracy NOTE After any major service especially if you have replaced worn components or hydraulic repairs you should re calib...

Page 8: ...e attachment is used select channel 1 Center Button used to Select Channel 1 Total 3 2 Check Change Display Readout The Weighlog 100 can be set to read Tons Eur setting or lbs USA setting The default...

Page 9: ...hannel being used and also to the Total channel 3 3 2 Static Weighing Static weighing means that the load is weighed while the bucket is stopped at the Reference sensor and held there The display will...

Page 10: ...show a weight 3 If the display reads 0 or within or 20 lbs this is within the repeatability of the Weighlog system and no further changes are needed The system is ready for operation 4 If the display...

Page 11: ...Dynamic Weighing Mode Step 1 Press and hold the Tare button for 5 seconds then release Display will flash Step 2 Lift empty bucket up above the sensors weight reading will be displayed Step 3 Press t...

Page 12: ...rial that has a known weight will be placed in the bucket The calibration number is changed and fine tuned until the Weighlog reads the weight in the bucket The amount of weight which is used needs to...

Page 13: ...undred pounds will result in a poor calibration 6 Lift the bucket or forks a few times noting the weight displayed each time Be sure to follow proper lifting procedures and roll bucket back before eac...

Page 14: ...g the correction calculation Correct Factor Existing Factor x True Weight Weighlog Reading 1 50 x 2100 1 26 2500 4 Reprogram Weighlog with new cal number of 1 26 If the Weighlog reading is more than t...

Page 15: ...econds The display will flash 5 times and then reset to 0 This does not affect the TOTAL channel 6 2 Reset Total 1 Select the TOTAL channel 2 Press and hold the remote enter button for 5 seconds The d...

Page 16: ...dealer NOTE All calibration settings sub totals grand total and weighing units will be reset to the factory default settings Error Message Err If the display shows Err there is no pressure signal bei...

Page 17: ...ontact dealer for replacement Head unit Beeps when Ref Dir sensors improperly installed Sensor relationship must be bucket is lowered vertical not horizontal with the D sensor on bottom Four dashes di...

Page 18: ...ning With forks and grapples the load must be centered and as close to the machine as possible Incorrect weighing units selected With bucket on ground display shows 0 00 unit is set to weigh in tons I...

Page 19: ...tons and turn on power If system resets all the settings are erased and returned to factory defaults If system does not reset contact local dealer Display will not turn on No power and or ground Check...

Page 20: ...9 Notes Page 18 9 Notes Channel 1 2 3 4 5 Attachment Product Weighing Mode Cal Factor...