GENERAL TECHNICAL DATA
Minimal pan diameter:
120 mm
Relative humidity:
10% to 90% non-condensing
Operation Ambient temperature:
0°C ÷ 40°C
Voltage tolerance:
Supply frequency:
-10% ÷ +6%
50 – 60 Hz
TECHNICAL DATA TABLE
MODELS
PCID-64ET…
PCID-68ET… PCIWD-64ET… PCID-84ET… PCID-44ET… PCID-88ET…
DIMENSIONS cm
40x60x31h
80x60x31h
40x60x31h
40x80x31h
40x40x31h
80x80x31h
POWER SUPPLY
400V~3
50/60Hz
400V~3
50/60Hz
400V~3
50/60Hz
400V~3
50/60Hz
400V~3
50/60Hz
400V~3
50/60Hz
MAXIMUM ABSORPTION A
14,4 A
29 A
7,2 A
14,4 A
7,2 A
29 A
MAXIMUM POWER kW
10 kW
20 kW
5 kW
10 kW
5 kW
20 kW
POWER SUPPLY CABLE
4x1,5 mm²
4x4mm²
4x1,5 mm²
4x1,5 mm²
4x1,5 mm²
4x4 mm²
MINIMUM VENTILATION IN
100 cm²
165 cm²
50 cm²
100 cm²
50 cm²
165 cm²
MINIMUM VENTILATION OUT
150 cm²
200 cm²
82 cm²
150 cm²
82 cm²
200 cm²
MAX AMBIENT TEMPERATURE
COMPARTMENT GENERATOR
35°C
35°C
35°C
35°C
35°C
35°C
INSTRUCTIONS FOR INSTALLATION
The data plate is on the front (see diagram in electric connection item) and has all the data necessary for the connection.
INSTALLATION
When fitting, the appliance must be leveled using a spirit level; slight differences of level can be adjusted by screwing
or unscrewing the adjustable feet. The main switch or the socket must be near the appliance and easily accessible.
It is advisable to place the appliance under an extractor hood so that steam is extracted rapidly. If the appliance is placed
near walls, dividing panels, kitchen furniture, decorative finishes, etc., these should be in flameproof material; otherwise
it is necessary to cover them with non-flammable material.
Above all, it is necessary to ensure that fire prevention standards are observed.
Always comply with the following points during installation:
-
Ensure that mains voltage complies with the voltage indicated on the specification table of the
appliance
-
All electrical installations must comply with local standards. All standards issued by national electrical authorities
must be complied with.
-
When circuit breakers are used, they must be suitable for a minimum of 30 mA.
-
Avoid obstruction of air intakes or outlets with objects (fabric, walls, etc).