background image

 

 

Product Fiche 

Name or trademark 

Lotus 

Notes 

Model identifier 

H470W-H570W  

 

Energy efficiency class 

A+  

 

Direct heat output 

7,0 kW 

-meaning the space heat output according to the product standard 

-rounded to the nearest one decimal place 

Energy efficiency index 

(EEI)

 

107,7 

-rounded to the nearest integer:          

 

Energy efficiency at 

nominal heat output 

  

80,5 % 

 

 

 

-Efficiency at nominal heat output according to the product  

 standard (rounded to the nearest one decimal place) 

Specific precautions 

that shall be taken 

when assembling, in- 

stalling or maintaining 

the local space heater.

  

Selected examples: 

- Fire protection and safety distances such as distances to combustible building   

  materials must be observed!                          

- An adequate supply of combustion air for the appliance must be guaranteed at 

  all times. Air-suction systems can interfere with the combustion air supply! 

 

   

 

Produktdatenblatt 

 

 

 

 

 

 

Name oder Waren Zeichen 

Lotus 

Hinweise

 

Modell Kennung 

H470W-H570W 

 

Energieeffizienzklasse 

A+  

 

Direkte Wärmeleistung 

7,0 kW 

 ist die Raumwärmeleistung nach den hEN‘s 

 auf die erste Dezimalstelle auf- bzw. abgerundet 

Energie Effizienz Index  (EEI)

 

107,7 

  

- wird auf die nächstliegen-          

de ganze Zahl gerundet: 

 

Brennstoff-Energie 

Effizienz bei Nenn 

Wärmeleistung 

80,5 % 

  

 

 Wirkungsgrad bei Nennwärmeleistung nach Norm (auf 

erste Dezimalstelle gerundet) 

Hinweise zu besonderen 

Vorkerungen für Zusammenbau, 

Installation oder 

Wartung des 

Einzelraumheizgerätes

 

Ausgewählte Beispiele: 

 

Die Brandschutz- und Sicherheitsabstande u.a. zu brennbaren Baustoffen 

müssen unbedingt eingehalten werden! 

 

Der Feuerstatte muss immer ausreichend Verbrennungsluft zuströmen können. 

Luftabsaugende Anlagen können die Verbrennungsluftversorgung stören!

 

Raison social ou marque 

Lotus 

Notes 

Désignation de modèle 

H470W-H570W 

 

Classe de performance 

énergétique 

A+ 

 

Puissance nominale 

7,0 kW 

-Indiquant la chaleur standard émis par l’appareil de chauffage 

Indice d’efficacité énergétique 

(EEI)

 

107,7 

  

-  arrondie à l'entier le plus proche:          

   

Rendement  par rapport à la 

puissance nominale 

80,5 % 

  

 

-Rendement à la puissance nominale en fonction de la norme de produit 

(arrondi à la décimale près) 

Precautions spécifique 

Pour l’assemblage, l’installation 

ou l’entretien du poêle à bois.

 

Exemples divers: 

Protection contre incendie et distances de sécurité aux matériaux inflammables doit être 

observé !   

Un correct apport d’air de combustion doit être garanti toujours, soit par grille de ventilation 

non blocable, soit par gainage d’air frais directement au poêle si des systèmes de ventilation 

mécanique interfère avec l’apport d’air.

 

 

 

 

Fiche produit 

Summary of Contents for H470W

Page 1: ...Assembly and User Instructions Fireplace Inserts Lotus H470W H570W Version 5 01 02 2017 ...

Page 2: ......

Page 3: ...new Lotus fireplace insert making for a warm and cosy beginning of an all new home life for you Technical Specifications Wood stove data testing to EN 13240 NS 3058 CE mark Model Flue gas temperatur e at nominal C Output kW Flue gas mass flow g s Flue Pa Weight Kg Distance to combustible material Behind the construction mm Next to the construction mm H470W 315 7 6 8 12 120 0 0 H570W 315 7 6 8 12 1...

Page 4: ...Drawing is an illustration and applies to normal inserts and wide models A Holes used for fastening the insert to the base B Set screws for adjustment of the insert in relation to the base ...

Page 5: ...wall Building in shall take place in connection with non inflammable materials only Virtually all installations are designed individually and in all cases the distance to inflammable matter must meet the values stated below Insulating material Useable are all AGI Q 132 registered insulating material All measurements are intended as minimum distances ...

Page 6: ...t For furniture a distance of 0 8 metres is recommended Distance to non inflammable material For non inflammable material no requirements apply The Chimney A good chimney draught is essential for how well a fireplace insert will burn Note that there should be access to cleaning doors The working height of the chimney should typically range between 3 5 and 4 5 metres Working height shall be underst...

Page 7: ...skew at one side and then at the other side and it is then put in place in the middle Combustion Air Supply A good and clean combustion will benefit from an adequate supply of air to the fire To allow for this it is however a condition that air be supplied to the room in which the fireplace insert has been put up In certainly the majority of rooms there will be an adequate amount of air particular...

Page 8: ...om of the fireplace insert stacked cross wise like a log house Put 2 spirit blocks in the middle and light these 2 Close the door ajar leaving an opening of appr 2 cm Open the air damper entirely under the damper pulling it all the way out Leave the fireplace insert like this for about 5 or 10 minutes before closing the door entirely and pushing the handle in locked position 3 Dampen the air dampe...

Page 9: ...tabilize so as to assume the appearance of a calmly burning fire 7 When the wood has burned down to the state of glows after about one hour start all over from item 4 Ashes The ashes may be dumped in the waste bin for scavenging The ashes should always have been cooled for one or two days before being dumped in the waste bin as there might otherwise still be glows which might set fire to waste or ...

Page 10: ...er or other matter may not be used Maintenance of Fireplace Insert It is recommended that the maintenance of your stove be performed by a qualified service engineer and that only spares recommended by the manufacturer be used Packings may look neat but they will collapse in the heat and will thus lose their ability to keep the fireplace insert tight Packings should be replaced as required since go...

Page 11: ...cm The essence of good combustion is that the wood should be appropriately dry at a humidity of 15 20 If your firewood is too wet making it burn will prove hard there will be no chimney draught it will smoke a lot and it will provide a lower degree of utilization as the water will have to evaporate first Further this may cause damage to your fireplace insert and chimney by way of shining soot and ...

Page 12: ...ll run hot and due care should be taken Any unauthorized change of the insert will render the warranty nil and void Operating Trouble If you have any problems with your Lotus fireplace insert you may find the cause below If not you will always be welcome to contact your Lotus distributor Your fireplace insert is hard to control it burns too quickly If your fireplace insert is new check that you ha...

Page 13: ...nd directions The chimney may be too short in relation to the roof ridge or trees may have grown up generating turbulence Making your fireplace insert burn proves hard or the fire may go out This may be due to a number of causes Those most typical are The damper is not open enough The firewood is too wet The draught in the chimney is too small it may have been blocked or is untight The layer of gl...

Page 14: ...Fireplace Insert H470W Fireplace Insert H570W ...

Page 15: ......

Page 16: ...osing gear This warranty shall lapse if this stove is not operated so as to comply with the directions for use and if deficiencies or similar are aimed to be are remedied by a person not authorized by Lotus Heating Systems A S This warranty does not cover damage caused by inappropriate non expert incompetent use of the stove If a product is returned to Lotus Heating Systems A S and the damage subs...

Page 17: ...n and the required manufacturing checks Johnny Ebstrup Lotus Heating Systems A S Product code Emission of CO 13 O Nominel Output kW Energy effi ciency Fire safety and Surface temperatur Release of dangerous substance Report no Lotus 370 Petite 0 09 5 8 77 Satisfies None RRF 29 16 4424 1 Lotus H470 H570 0 09 6 84 Satisfies None RRF 29 14 3815 Lotus H470W H570W 0 10 7 80 5 Satisfies None RRF 29 13 3...

Page 18: ...nergie Effizienz bei Nenn Wärmeleistung 80 5 Wirkungsgrad bei Nennwärmeleistung nach Norm auf erste Dezimalstelle gerundet Hinweise zu besonderen Vorkerungen für Zusammenbau Installation oder Wartung des Einzelraumheizgerätes Ausgewählte Beispiele Die Brandschutz und Sicherheitsabstande u a zu brennbaren Baustoffen müssen unbedingt eingehalten werden Der Feuerstatte muss immer ausreichend Verbrenn...

Page 19: ......

Reviews: