Electrical Connection
The mains electricity supply MUST BE DISCONNECTED before Attempting
Installation/maintenance or handling of any kind.
1).
This unit is designed for permanent installation to the mains.
2).
The power supply should be
earthed and fused at 3amps.
3).
Warning: A residue Circuit
Device (RED) Must be fitted to
the mains supply.
4).
For permanent installation into
the mains, it is necessary to
comply with the regulations of the
Local Electrical Authority.
!
!
Safety/Installation/Electrical Instructions for all models
WHY FILTER?
Pond pollutants are introduced via an accumulation of solids settling at the bottom. These can be
categorised into two groups. I. Fish waste products - faeces, ammonia, dissolved carbon dioxide,
etc. 2.. Decaying vegetation and uneaten fish food.
The solids quickly dissolve into the pond producing harmful bi-products, which are hazardous to
fish health and may cause the water to become cloudy. Sunlight encourages algae, which makes
the pond water green. The Green Genie Biological Filter and Ultra Violet Steriliser is designed to
provide clean, clear water. The Biological effect ensures that the pond water is kept free of
pollutants that can kill fish and plant life. The UV kills algae and harmful bacteria thereby making
the pond water clear.
MECHANICAL FILTRATION
Mechanical filtration simply means the removal of the solids and prevention of their return to the
pond. This is achieved by passing the water over layers, or layer of foam in the bio-filter.
BIOLOGICAL PURIFICATION
This is achieved by colonising the plastic filter medium with 'friendly' bacteria and micro-
organisms which, when mature, digest pollutants thus neutralising harmful ammonia and nitrates.
UV STERILISATION
This occurs when the UV light penetrates the water as the water passes through the water
chamber. It kills the algae and harmful bacteria thereby making the pond water clear.
INSTALLATION -
THIS APPLIANCE IS NOT SUBMERSIBLE
Connect a hose from the pump to the multi hosetail fitting on the top. The outlet water should be
routed back to the pond.
On initial set up allow the unit to operate for a week before
switching on the electricity supply to the ultraviolet steriliser. This allows the filter to be
colonised by friendly bacteria.
Always run 24 hours a day for maximum efficiency.
5).
Consult a qualified electrician if in doubt about any aspect of electrical wiring.
6).
The Wires in the cable are colour coded as follows:
Brown
- Live
Green/Yellow
- Earth
Blue
- Neutral
7).
If you need to extend the cable on this unit, you should use a suitable length of
3 core cable and a Lotus waterproof (IP68) cable connector. (Ask your
retailer).
WARNING: Never look directly at the U.V. bulb when it is switched on.
The UV light generated by the bulb can cause damage to eyes and
skin. The Unit is supplied With a translucent hosetail which will glow
allowing you to see that the U.V. is Working.
Maintenance for all Models
CLEANING
The efficiency of the filter depends on the foam and the Flocor™ being colonised. The foams should not be
cleaned unless water is passing down the overfiow pipe. Usually only the top layer needs to be cleaned.
Remove and shake clean whilst hosing with clean water. The Flocor filter medium should never be cleaned:
however it can be removed to facilitate the removal of silt from the bottom of the filter box. Please note that
the foam should be replaced every year.
ULTRA VIOLET STERILISER MAINTENANCE
When installing your Green Genie, if you need to use an extension lead use only the correct cable and
waterproof (IP68) or weatherproof (IP67) cable connectors. Remember that pets and wildlife often damage
cable, so it is advisable to run your cable through a length of hose and protect the connectors with an
arrangement of rocks or bricks.
No routine maintenance is required. Routine replacement of the lamp is recommended no later than 8000
hours, or 12 months, whichever is sooner.
REPLACING BULB & QUARTZ SLEEVE
(all "wear and tear" items)
Models 2500, 3500 & 6500: (RIGHT)
1) Isolate Steriliser from mains supply and switch off Genie.
2)
Remove the two lid-retaining (self-tapping) screws.
3)
Remove Genie lid.
4)
Undo the hosetail by turning anti-clockwise.
5)
Remove spray bar by unwinding anti-clockwise.
6)
Separate the base from the lid. Pull the cable through as
you do so (remove hosetail on 12500 model).
7)
Disconnect the lamp holders and pull out the bulb from
housing.
REMOVING THE QUARTZ SLEEVE
8)
Unscrew the two compression fittings from the ends of the water chamber and remove '0'
rings.
9)
Slide out quartz sleeve; handle with care as it is brittle. Clean the quartz sleeve with
domestic acid or ammonia based cleaning solution rinsing thoroughly afterwards. If quartz
sleeve is excessively scratched, then replace. Periodically check the white UV Body/Bodies,
as they may need replacing if they show signs of deterioration.
10)
Refit the quartz sleeve with the 'O' rings and tighten up the compression fittings by hand.
11)
Replace the lamp and refit the lamp holders.
REPLACING UV BULB & QUARTZ SLEEVE - Models: 12500, 24000 & 48000
Models:2500, 3500 & 6500
1.
2.
3.
4.
5.
6.
I, Remove hosetail & seal/washer.
2, Remove push clips and lid.
3. Remove lamp holders from UV bulb,
4, Remove UV bulb,
5, Unscrew endcaps at each end of UV chamber.
6, Remove '0 rings' and remove quartz sleeve, To re-
assemble reverse the above procedure,
If you are unsure whether or not the unit is working,
place a piece of white paper or card at the end close
Push down to insert
cable, release to secure.
MODELS:
24000
48000
To Mains
* See Electrical
Instructions
Inside
Overflow
UV/Water
Chamber
Water Inlet
VariFlow Valve**
***Filtration
Foam -
Dimple Side Up
Filter Media
*** Wear & Tear
Items
Outlet
to Pond
ALL IMAGES ARE FOR
ILLUSTRATION PURPOSES ONLY
** VariFlow Valve where fitted.
To Mains
* See Electrical
Instructions
Inside
UV/Water
Chamber
Water Inlet
VariFlow Valve**
***Filtration
Foam -
Dimple Side Up
Filter Media
Outlet
to Pond
To Mains
* See Electrical
Instructions
Inside
UV/Water
Chamber
Water Inlet
VariFlow Valve**
Outlet
to Pond
***Filtration
Foam -
Dimple Side
Up
Filter Media
MODELS:
2500
3500
6500
MODEL:
12500
*** Wear & Tear
Items