background image

INSTALLATION

Instructions in original language

13

3 INSTALLATION

3.1

Delivery checks

On delivery, it is important to check the following:
 

·

External conditions of the packaging

·

The general status of the equipment

·

The conformity of the model with the information in the technical data plate and the instruction manual

·

The conformity of the equipment and components to the order form

 

3.2

Removing the packaging

While removing the packaging, take care not to damage the appliance. Remove the protective film from the
stainless steel and eliminate any traces of glue. Do not smoke. Perform this operation away from sources of
heat and wear protective gloves. Do not disperse packaging material in the environment, keep it out of the
reach of children and dispose in compliance with current legislation.
 

3.3

Mechanical installation

Place the appliance on a flat base. Adjust and stabilise the appliance by acting on the support feet. Make
sure that the surrounding walls and/or equipment are capable of withstanding the heat emitted by this
appliance. Connect the water supply (if necessary).
 

Caution

 

Do not install the appliance near equipment/machines used in cold processes. If the appliance
has to be installed close to cold process equipment, it is advisable to install non-combustible
thermal insulating material and/or neutral elements between them.

 

3.4

Electrical/gas connections

Before being offered for sale on the market, the appliance was subjected to gas and electrical testing (as
required). The appliance is supplied without a power cable. The installation technician must connect the
equipment in compliance with current safety regulations on the basis of the power of the appliance.

Note

 

The ID plate is located in the compartment inside the door for appliances with compartments, or on
the left side for appliances with an oven or a top. A second plate with the model and serial number is
located inside the dashboard and a third is included with the certificate of conformity. The serial
number can also be tracked from the sales document (after 2008). The plate has all the data needed
for correct electrical installation. The installation and possible conversion to another power supply
voltage (if envisaged) must be implemented exclusively by professionally qualified and authorized
personnel. Before using the appliance, carefully clean all surfaces intended to come into contact with
food.

 

Summary of Contents for FE-10

Page 1: ...ROFESSIONAL USE FEM 6 FEM 2 6 FE 8 FE 2 8 FE 10 FE 2 10 FME 10 FME 2 10 FME 15 FME 2 15 FPE 20 FPE 25 FMPE 20 FMPE 25 FMPE 30 Model LIBR ISTR FE FME FPE Code 563009301 Review 1 Edition date 28 01 2020...

Page 2: ...ronic equipment 11 2 3 Technical data table 12 3 INSTALLATION 13 3 1 Delivery checks 13 3 2 Removing the packaging 13 3 3 Mechanical installation 13 3 4 Electrical gas connections 13 4 INSTRUCTIONS FO...

Page 3: ...INTRODUCTION Instructions in original language 3 1 INTRODUCTION 1 1 Installation drawing FIG 1 FE 10 FE 2 10 A Data Plate B Electrical connection...

Page 4: ...INTRODUCTION Instructions in original language 4 FIG 2 FEM 6 FE 8 FEM 2 6 FE 2 8 A Data Plate B Electrical connection...

Page 5: ...INTRODUCTION Instructions in original language 5 FIG 3 FME 10 FME 15 A Data Plate B Electrical connection...

Page 6: ...INTRODUCTION Instructions in original language 6 FIG 4 FMPE 20 FMPE 25 FMPE 30 A Data Plate B Electrical connection FIG 5 FPE 20 FPE 25 A Data Plate B Electrical connection...

Page 7: ...ions in original language 7 WIRING DIAGRAM FEM 6 FEM 2 6 1 Switch 2 Microswitch 3 Power supply terminal board 4 Heating element 5 White indicator light 6 Green indicator light 7 Contactor 8 Safety the...

Page 8: ...2 8 FE 10 FE 2 10 FME 10 FME 2 10 FME 15 FME 2 15 FPE 20 FPE 25 FMPE 20 FMPE 25 1 Switch 2 Microswitch 3 Power supply terminal board 4 Switching terminal board 5 Heating element 6 White indicator ligh...

Page 9: ...ginal language 9 WIRING DIAGRAM FMPE 30 1 Switch 2 Microswitch 3 Power supply terminal board 4 Switching terminal board 5 Heating element 6 White indicator light 7 Green indicator light 8 Contactor 9...

Page 10: ...ctrical safety of this equipment is only ensured when it is correctly connected to an effective ground earth system as required by current electrical safety standards The manufacturer cannot be held l...

Page 11: ...uipment to the distributor when purchasing a new one Plus being RoHS compatible in accordance with Directive 2011 65 EU on the restriction of the use of certain hazardous substances in electrical and...

Page 12: ...0x70x85h 400V 3N 50 60Hz 13 9 5 x 1 5 mm FME 2 15 80x70x85h 400V 3N 50 60Hz 26 18 5 x 1 5 mm FPE 20 60x70x25h 400V 3N 50 60Hz 9 5 6 6 5 x 1 5 mm FMPE 20 60x70x85h 400V 3N 50 60Hz 9 5 6 6 5 x 1 5 mm FP...

Page 13: ...install the appliance near equipment machines used in cold processes If the appliance has to be installed close to cold process equipment it is advisable to install non combustible thermal insulating...

Page 14: ...t so that the device can be fully disconnected from the mains this device must have a contact aperture of at least 3 mm The connection terminal is located behind the rear wall Proceed as follows to in...

Page 15: ...ning or maintenance operation Fill the tank with oil up to the lower reference mark 4 2 Turning the appliance on off Turn on the switch located upstream of the appliance Turn the knob from 0 to the de...

Page 16: ...tarting cold The thermostat can be set to the maximum only after the entire mass has melted 4 4 Top appliances bowl emptying The user is required to have a suitable recipient for emptying the water oi...

Page 17: ...d its safety systems Warning For maintenance replacement of components order and use only original spare parts Replacing parts must exclusively be performed by authorised and or qualified personnel Wh...

Page 18: ...ELEMENT remove the panel and remove the wires connecting the heating element Unscrew the two 8 mm screws that fasten the bracket to the heating element and pull out the bracket until it can be removed...

Page 19: ...available commercially but a diluted solution of acetic acid can also be used To clean STAINLESS STEEL appliances it is advisable to use detergents specifically formulated for this material For minor...

Reviews: