INSTALLATION

Translation of the original instructions

11

Warning

 

Installation  operations,  any  conversion  to  other  types  of  gas  and  start-up  must  only  be
performed by qualified personnel, in accordance with current regulations.

 

Gas systems, electrical connections and premises where the appliances are installed must comply with
current regulations in the country of installation; in particular, the appliance must be installed in a room with
good ventilation, if possible under a suction hood to ensure complete evacuation of the exhaust gases
formed during combustion. The air required for combustion is 2 m3/h per kW of installed power. The
appliance can be installed alone or in series with other appliances in our production range. A minimum
distance of 10 cm between appliances must be respected to prevent contact with any walls made of
flammable material; furthermore, appropriate measures should also be adopted to ensure the thermal
insulation of flammable parts, such as the installation of heat shields; take special care to ensure that
appliances are installed in an appropriate and safe manner. The support feet can be adjustable in height and
any unevenness can therefore be eliminated.
 

ELECTRICAL CONNECTION

Caution

 

In accordance with international provisions, when connecting the appliance an automatic
device must be installed up-line of it so that the device can be fully disconnected from the
mains; this device must have a contact aperture of at least 3 mm.

The connection terminal is located behind the rear wall. Proceed as follows to install the power supply cable:
 

·

Remove the rear panel.

·

Pass the new connection cable through the cable gland, connect the leads to the corresponding terminal

on the terminal block and fasten them securely.

·

Lock the cable with the cable gland and refit the panel. The earth/ground lead must be longer than the

others so that if the cable gland breaks it is disconnected after the power cables.

 

Note

 

Make sure that the mains voltage complies with the data on the appliance's ID plate and that there is
good conductivity to earth/ground. Pay attention when inserting leads to ensure they do not obstruct
the normal course of work and routine appliance cleaning operations. Also make sure that the power
cable is never pulled taut and is not placed in contact with sources of heat.

Note

 

The connection cable must have the following characteristics: it must be silicone type (to
withstand temperatures of 180 °C), and must have an appropriate cross-section for the power
of the appliance (see technical data table).

 

EQUIPOTENTIAL

 
The appliance must be connected to an equipotential system. The connecting screw is located on the rear of
the appliance and is marked by the yellow symbol above it.
 

Warning

 

The manufacturer is not liable for and does not indemnify damages caused by incorrect
inadequate installations that do not comply with these instructions.

Summary of Contents for F18-74ETD

Page 1: ...ons ELECTRIC FRYERS FOR PROFESSIONAL USE F18 74ETD F18 74ETDP F18 74ETDPS F2 18 78ETD F2 18 78ETDP F2 18 78ETDPS Model LIBR ISTR F70ED Code 563047900 Review 1 Edition date 31 03 2021 Language English...

Page 2: ...ormation RAEE Directive on waste electrical and electronic equipment 9 2 3 Technical data table 9 3 INSTALLATION 10 3 1 Delivery checks 10 3 2 Removing the packaging 10 3 3 Mechanical installation 10...

Page 3: ...INTRODUCTION Translation of the original instructions 3 1 INTRODUCTION 1 1 Installation drawing FIG 1 F 7 E A Data Plate B Electrical connection...

Page 4: ...INTRODUCTION Translation of the original instructions 4 1 2 Components FIG B ROTARY RESISTANCE 1 O rings 2 Rotary heating element...

Page 5: ...INTRODUCTION Translation of the original instructions 5 WIRING DIAGRAM C A Oil basin on the floor B Oil drain cock closed C Oil drain cock open D Oil basin in the guideway E Heater lowered...

Page 6: ...ETDP ETDPS models 7 2 Lift motor for ETDPS models 8 2 Fan motor 9 1 USB socket 10 3 Grill resistor 11 1 Electronic hardware control board 12 1 Touch electronic board 13 1 Liquid presence sensor 14 2...

Page 7: ...INTRODUCTION Translation of the original instructions 7 1 3 Example installation of the appliance...

Page 8: ...electrical safety of this equipment is only ensured when it is correctly connected to an effective ground earth system as required by current electrical safety standards The manufacturer cannot be hel...

Page 9: ...nt and human health may be due to the misuse of the same equipment or parts of it The symbol next to the rating plate indicates the obligation of separate collection The penalties provided for in the...

Page 10: ...not install the appliance near equipment machines used in cold processes If the appliance has to be installed close to cold process equipment it is advisable to install non combustible thermal insulat...

Page 11: ...of it so that the device can be fully disconnected from the mains this device must have a contact aperture of at least 3 mm The connection terminal is located behind the rear wall Proceed as follows t...

Page 12: ...body to avoid burns caused by high temperatures After switching off the appliance wait for a sufficient time for it to cool before carrying out any cleaning or maintenance operation Fill the tank with...

Page 13: ...e and its safety systems Warning For maintenance replacement of components order and use only original spare parts Replacing parts must exclusively be performed by authorised and or qualified personne...

Page 14: ...el disconnect the two probe contacts and unscrew the fastening coupling Now from inside the tank unscrew the bulb holder bracket and slide out the probe PUMP Remove the front panel and the rear sectio...

Page 15: ...are available commercially but a diluted solution of acetic acid can also be used To clean STAINLESS STEEL appliances it is advisable to use detergents specifically formulated for this material For m...

Reviews: