background image

MAINTENANCE

Translation of the original instructions

16

5.2

Spare parts

It is possible to replace parts such as the valve, the piezoelectric or the ignition control unit (depending on
the type of appliance) or the gas pipes easily and quickly.
To replace such parts, proceed as follows:
 

·

SWITCH and THERMOSTAT: Remove the knob and open the panel, unscrew the two screws that fasten

the switch to the panel, remove all the electrical connections and proceed with replacement. The
thermostat and switch are fastened together by a metal bracket

 

·

ROTARY HEATING ELEMENT; remove the panel and remove the wires connecting the heating element.

Unscrew the two 8 mm screws that fasten the bracket to the heating element and pull out the bracket
until it can be removed. At this point, the heating element can be removed from inside the bowl, pushing
it towards the draught diverter. Also replace the 3 o-rings (see point 1 in figure B) and apply a bit of
grease to facilitate the operation.

 
 

Note

 

It  is  recommended  to  replace  the  three  o-rings  once  a  year  as  they  are  subject  to  wear  and,  with
time, can cause leaks

 

Caution

 

WHAT TO DO IN THE EVENT OF FAULTS:

Close the gas connection cock and/or switch off the power using the up-line device. Notify
customer service.

 

Warning

 

MEASURES TO BE TAKEN IF THE APPLIANCE IS NOT TO BE USED FOR A LONG TIME:

Close the gas cock and/or disconnect the power supply. Clean the system as specified above.

Summary of Contents for F13-74ETX

Page 1: ...FRYERS FOR PROFESSIONAL USE F13 74ETX F2 13 78ETX F18 74ETX F2 18 78ETX F13T 74ETX F2 13T 78ETX F2 8 74ETX F2 8T 74ETX Model LIBR ISTR FX70E POT Code 563016104 Review 1 Edition date 02 12 2019 Langua...

Page 2: ...on waste electrical and electronic equipment 10 2 3 Technical data table 10 3 INSTALLATION 11 3 1 Delivery checks 11 3 2 Removing the packaging 11 3 3 Mechanical installation 11 3 4 Electrical gas con...

Page 3: ...INTRODUCTION Translation of the original instructions 3 1 INTRODUCTION 1 1 Installation drawing FIG 1 F 7 E FIG 2 F T 7 E A Data Plate B Electrical connection...

Page 4: ...ol knob to zero but the system remains operational until the problem that caused the intervention is resolved Contacts 80 and 81 are provided to enable the fryer to be controlled from a remote locatio...

Page 5: ...tions 5 WIRING DIAGRAM D 1 Cicada 2 Switch 3 Microswitch 4 Power supply terminal board 5 Heating element 6 Resistance voltage drop 7 White indicator light 8 Red indicator light 9 Green indicator light...

Page 6: ...of the original instructions 6 Electrical technical data table MODEL WIRING DIAGRAMS F13 74ETX D F13T 74ETX D F2 13 78ETX D D F2 13T 78ETX D D F18 74ETX D F2 18 78ETX D D F2 8 74ETX D D F2 8T 74ETX D...

Page 7: ...INTRODUCTION Translation of the original instructions 7 1 3 Fixing feet...

Page 8: ...INTRODUCTION Translation of the original instructions 8 1 4 Example installation of the appliance...

Page 9: ...electrical safety of this equipment is only ensured when it is correctly connected to an effective ground earth system as required by current electrical safety standards The manufacturer cannot be hel...

Page 10: ...ipment are those provided for by the national transpositions of European Directives 2012 19 EU 2 3 Technical data table Electrical technical data table F S70EX MODEL DIMENSIONS POWER SUPPLY MAXIMUM PO...

Page 11: ...not install the appliance near equipment machines used in cold processes If the appliance has to be installed close to cold process equipment it is advisable to install non combustible thermal insulat...

Page 12: ...of it so that the device can be fully disconnected from the mains this device must have a contact aperture of at least 3 mm The connection terminal is located behind the rear wall Proceed as follows t...

Page 13: ...leaning or maintenance operation Fill the tank with oil up to the lower reference mark 4 2 Turning the appliance on off Turn on the switch located upstream of the appliance Turn the knob from 0 to the...

Page 14: ...at during the emptying stage the oil does not overflow and does not represent a hazard We recommend filtering the oil every day at the end of work and changing it when necessary Turn the oil drain coc...

Page 15: ...e and its safety systems Warning For maintenance replacement of components order and use only original spare parts Replacing parts must exclusively be performed by authorised and or qualified personne...

Page 16: ...g the heating element Unscrew the two 8 mm screws that fasten the bracket to the heating element and pull out the bracket until it can be removed At this point the heating element can be removed from...

Page 17: ...are available commercially but a diluted solution of acetic acid can also be used To clean STAINLESS STEEL appliances it is advisable to use detergents specifically formulated for this material For m...

Reviews: