5.2

Spare parts

It is possible to replace parts such as the valve, the piezoelectric or the ignition control unit (depending on
the type of appliance) or the gas pipes easily and quickly.
To replace such parts, proceed as follows:
 

·

SWITCH and THERMOSTAT: Remove the knob and open the panel, unscrew the two screws that fasten

the switch to the panel, remove all the electrical connections and proceed with replacement. The
thermostat and switch are fastened together by a metal bracket

 

·

ROTARY HEATING ELEMENT; remove the panel and remove the wires connecting the heating element.

Unscrew the two 8 mm screws that fasten the bracket to the heating element and pull out the bracket
until it can be removed. At this point, the heating element can be removed from inside the bowl, pushing
it towards the draught diverter. Also replace the 3 o-rings (see point 1 in figure B) and apply a bit of
grease to facilitate the operation.

 
 

Note

 

It  is  recommended  to  replace  the  three  o-rings  once  a  year  as  they  are  subject  to  wear  and,  with
time, can cause leaks

 

Caution

 

WHAT TO DO IN THE EVENT OF FAULTS:

Close the gas connection cock and/or switch off the power using the up-line device. Notify
customer service.

 

Warning

 

MEASURES TO BE TAKEN IF THE APPLIANCE IS NOT TO BE USED FOR A LONG TIME:

Close the gas cock and/or disconnect the power supply. Clean the system as specified above.

Summary of Contents for F13-74ET

Page 1: ...CTRIC FRYERS FOR PROFESSIONAL USE F13 74ET F2 13 78ET F18 74ET F2 18 78ET F13T 74ET F2 13T 78ET F2 8 74ET F2 8T 74ET Model LIBR ISTR F70E POT Code 563005703 Review 1 Edition date 30 01 2019 Language E...

Page 2: ...electrical and electronic equipment 10 2 3 Technical data table 10 3 INSTALLATION 12 3 1 Delivery checks 12 3 2 Removing the packaging 12 3 3 Mechanical installation 12 3 4 Electrical gas connections...

Page 3: ...INTRODUCTION Translation of the original instructions 3 1 INTRODUCTION 1 1 Installation drawing FIG 1 F 7 E FIG 2 F T 7 E A Data Plate B Electrical connection...

Page 4: ...INTRODUCTION Translation of the original instructions 4 1 2 Components FIG B ROTARY RESISTANCE 1 O rings 2 Rotary heating element...

Page 5: ...5 WIRING DIAGRAM C 1 Switch 2 Microswitch 3 Power supply terminal board 4 Power switching terminal block 5 Resistor switching terminal block 6 Heating element 7 White indicator light 8 Green indicator...

Page 6: ...lation of the original instructions 6 WIRING DIAGRAM D 1 Switch 2 Microswitch 3 Power supply terminal board 4 Heating element 5 White indicator light 6 Green indicator light 7 Contactor 8 Thermostat 9...

Page 7: ...lation of the original instructions 7 Wiring diagram reference table MODELS TERMINAL BOARD 1 TERMINAL BOARD 2 F13 74ET C F13T 74ET C F2 13 78ET C C F2 13T 78ET C C F18 74ET D F2 18 78ET D D F2 8 74ET...

Page 8: ...INTRODUCTION Translation of the original instructions 8 1 3 Example installation of the appliance...

Page 9: ...electrical safety of this equipment is only ensured when it is correctly connected to an effective ground earth system as required by current electrical safety standards The manufacturer cannot be hel...

Page 10: ...lection The penalties provided for in the event of improper disposal of RAEE Waste Electrical and Electronic Equipment are those provided for by the national transpositions of European Directives 2012...

Page 11: ...INFORMATION Translation of the original instructions 11 DESIGN ASSEMBLY TRANSFORMATION ELECTRICAL LINKING TERMINAL BLOCK PERNIONS see technical data table POWER SUPPLY CONNECTION HEATING ELEMENT CONN...

Page 12: ...not install the appliance near equipment machines used in cold processes If the appliance has to be installed close to cold process equipment it is advisable to install non combustible thermal insulat...

Page 13: ...of it so that the device can be fully disconnected from the mains this device must have a contact aperture of at least 3 mm The connection terminal is located behind the rear wall Proceed as follows t...

Page 14: ...leaning or maintenance operation Fill the tank with oil up to the lower reference mark 4 2 Turning the appliance on off Turn on the switch located upstream of the appliance Turn the knob from 0 to the...

Page 15: ...at during the emptying stage the oil does not overflow and does not represent a hazard We recommend filtering the oil every day at the end of work and changing it when necessary Turn the oil drain coc...

Page 16: ...e and its safety systems Warning For maintenance replacement of components order and use only original spare parts Replacing parts must exclusively be performed by authorised and or qualified personne...

Page 17: ...g the heating element Unscrew the two 8 mm screws that fasten the bracket to the heating element and pull out the bracket until it can be removed At this point the heating element can be removed from...

Page 18: ...are available commercially but a diluted solution of acetic acid can also be used To clean STAINLESS STEEL appliances it is advisable to use detergents specifically formulated for this material For m...

Reviews: