MAINTENANCE

Translation of the original instructions

17

7 MAINTENANCE

7.1

Routine

When using the appliance over time, it is essential to perform regular maintenance to ensure safe operation.
We therefore recommend stipulating a service contract.
 

Caution

 

Maintenance  must  only  be  performed  by  specialist  personnel  in  compliance  with  current
regulations and our own instructions.

 

Before carrying out any maintenance and/or cleaning operation:
 

·

Disconnect the appliance from the mains power supply and/or close the gas.

·

Wait for a sufficient time for the appliance to cool down.

·

Do not wash the appliance with direct or high-pressure jets of water, since any infiltration of water into the

electrical components could jeopardise correct operation of the appliance and its safety systems.

 

Warning

 

For maintenance/replacement of components, order and use only original spare parts.

 

Replacing parts must exclusively be performed by authorised and/or qualified personnel. When replacing the
electrical components of the machine and the electrical panels, scrupulously follow the technical
characteristics for the replacement component indicated on the component itself. The appliance does not
require any special maintenance but during the use of the equipment it is advisable to check the following at
least once a year (possibly increasing the frequency depending on the degree of use):
 

·

The status of connections especially on the terminal board and the power supply cable, as well as the

status of the gas connections;

·

The operating condition of the various components (perform a functional test);

·

For appliances fitted with rotary resistances, remove the hub, grease it and replace the three o-ring seals

to avoid possible leaks.

7.2

Replacing the main burner nozzle

·

Remove the front screws fastening the dashboard/panel and pull it outwards

·

Detach the starter cable

·

Using a suitable wrench, unscrew the nozzle and replace it with an appropriate new one

·

The main burner does not require any regulation of the primary air

 

7.3

Replacing the pilot burner nozzle

The pilot burner flame has a fixed air supply. The only necessary item is replacement of the nozzle
depending on the type of gas used (see technical data table).
 

·

Unscrew the coupling connecting the pilot tube to the pilot itself and slide out the nozzle to be replaced

·

Replace the nozzle with the appropriate version and make sure that, after ignition, the flame correctly

touches the tip of the thermocouple

 

Summary of Contents for 5630511A0

Page 1: ...ation and operating instructions GAS FRY TOP FOR PROFESSIONAL USE FT 558GS FT 110GS Model LIBR ISTR FT110G Code 5630511A0 Review 1 Edition date 01 06 2022 Language English LOTUS S p A Via Calmaor 46 31020 San Vendemiano 39 0438 778020 39 0438 778277 ...

Page 2: ...lectrical gas connections 10 4 BURNERS TECHNICAL DATA TABLE ITGB 14 4 1 Burners technical data table 14 6 INSTRUCTIONS FOR USE 15 6 1 General information 15 6 2 Switching the pilot burner on 15 6 3 Starting the main burner and adjusting the temperature 15 6 4 Switching the main burner off 15 6 5 Switching the appliance off 16 6 6 Emptying the container 16 6 7 Observations and advice 16 7 MAINTENAN...

Page 3: ...INTRODUCTION Translation of the original instructions 3 1 INTRODUCTION 1 1 Installation drawing FIG 1 FT 558GS A Data Plate C Gas connection ...

Page 4: ...INTRODUCTION Translation of the original instructions 4 FIG 2 FT 110GS A Data Plate C Gas connection ...

Page 5: ...lation of the original instructions 5 1 2 Components FIG A 1 Valve knob 2 Dashboard bracket 3 Piezoelectric 4 Valve 5 Gas pipes 6 Extends drainage 7 Pilot 8 Ignition spark plug 9 Injector 10 Bracket 11 Fat collection pan ...

Page 6: ...INTRODUCTION Translation of the original instructions 6 FIG B A Piezoelectric FIG C 1 Bracket 2 Pilot light nozzle 3 Ignition spark plug 4 Extends drainage ...

Page 7: ...INTRODUCTION Translation of the original instructions 7 1 3 Example installation of the appliance ...

Page 8: ... electrical safety of this equipment is only ensured when it is correctly connected to an effective ground earth system as required by current electrical safety standards The manufacturer cannot be held liable for any damage caused if the system is not connected to ground earth Before carrying out any cleaning or maintenance tasks on the equipment unplug it from the electricity mains In the event ...

Page 9: ...uctions 9 2 2 Technical data table Technical data table FT S110G MODEL DIMENSIONS GAS FITTING ISO 7 1 RATED TOTAL GAS FLOW kW FT 558GS 80x55x90h R 1 2GM 10 FT 1110GS 100x110x90h R 1 2GM 24 L Smooth plate R Ribbed plate LR smooth 1 2 ribbed S Chrome plate ...

Page 10: ... install the appliance near equipment machines used in cold processes If the appliance has to be installed close to cold process equipment it is advisable to install non combustible thermal insulating material and or neutral elements between them 3 4 Electrical gas connections Before being offered for sale on the market the appliance was subjected to gas and electrical testing as required The appl...

Page 11: ...hat do not cause corrosion such as solutions of soapy water or leak detectors All our appliances are subjected to detailed examination the type of gas pressure in use and the pertinent category are indicated on the data plate see attachment Note The year of construction of the appliance is indicated under N on the data plate The first 2 digits indicate the year of construction THERMAL OUTPUT CONTR...

Page 12: ...ined in a bag included in the supply and are marked in hundredths of mm see Burners technical data table INSTRUCTIONS FOR EVACUATING EXHAUST GASES A type devices see data plate A type appliances must discharge combustion products into appropriate hoods or similar devices connected to an efficient fume stack or directly to the outside Natural evacuation Fig 1 If this is not possible using an air su...

Page 13: ...liance must be possible only by hand If the installation is under a hood the terminal part of the appliance s exhaust pipe must be at least 1 8 meters from the appliance s support surface ground The outlet section of the exhaust pipes for combustion products must be placed within the perimeter in relation to the hood itself 1 Windproof fume stack fig 3 Extractor hood fig 4 2 Servo system B11 type ...

Page 14: ...S110G 12 68 kWh KG G30 BUTANE 30 mbar 12 87 kWh KG G31 PROPANE 37 mbar 9 45 kWh m3st G20 METHANE H 20 mbar FT 558GS Burner injector 1 100 mm 4 x 75 4 x 75 4 x 110 Pilot injector 1 100 mm 19 19 27 Consumption kg h 0 391 kg h 0 389 m3 st h 0 529 FT 1110GS Burner injector 1 100 mm 8 x 80 8 x 80 8 x 125 Pilot injector 1 100 mm 19 19 27 Consumption kg h 0 946 kg h 0 932 m3 st h 1 270 ...

Page 15: ...cool before carrying out any cleaning or maintenance operation If smoke is emitted during commissioning leave the system to run on no load for about one hour or until the smell has disappeared 6 2 Switching the pilot burner on Press and turn the valve knob fig A pos 1 into star position Keep the knob pressed down then press the piezo button 03 repeatedly The flame will ignite automatically and is ...

Page 16: ...lot burner 6 6 Emptying the container This rack should be checked regularly and emptied before it is full In any case the rack must be cleaned after switching off the appliance 6 7 Observations and advice For appliances with two cooking zones the temperature can be set differently on the two halves of the plate or only one half be used Warning Sharp and pointed tools can damage the chrome finished...

Page 17: ...ndicated on the component itself The appliance does not require any special maintenance but during the use of the equipment it is advisable to check the following at least once a year possibly increasing the frequency depending on the degree of use The status of connections especially on the terminal board and the power supply cable as well as the status of the gas connections The operating condit...

Page 18: ...front panel unscrew the gas connection screw couplings and extract the valve bulb then replace the faulty parts and install the new ones in sequence THERMOCOUPLE fig A pos 6 unscrew the pilot burner coupling unscrew the valve coupling in the same way and replace the element SPARK PLUG fig A pos 8 unscrew the coupling remove the damaged one and replace it Caution WHAT TO DO IN THE EVENT OF FAULTS C...

Page 19: ...s are available commercially but a diluted solution of acetic acid can also be used To clean STAINLESS STEEL appliances it is advisable to use detergents specifically formulated for this material For minor cleaning a mild washing up liquid solution may also be used Do not wash the appliance with jets of water under pressure Avoid using detergents containing abrasive powders or bleaches of any kind...

Reviews: