background image

L O O P

EXTERNAL I/O

POWER

INPUT

WARNING

 : TO REDUCE THE RISK OF ELECTRIC SHOCK,

        

DO NOT REMOVE COVER (OR BACK).

       

NO USER-SERVICEABLE PARTS INSIDE.

         

REFER SERVICING TO QUALIFIED

             

SERVICE PERSONNEL.

RISK OF ELECTRIC SHOCK
          DO NOT OPEN

IN

CALL

A U D I O

MONITOR

O U T

AUDIO

 

Back Panel 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

1.  POWER INPUT 

Connects to the Power cord. 

 

 

 

2.  EXTERNAL I/O 

Connects to a PC for Remote Control via RS-232 or to an Alarm Block. (see appendix 6 for more info) 

 

3.  75/HI 

When using the LOOP function, allows for HI impedance or 75ohms. 

 

4.  VIDEO INPUT (1-16) 

Connects to a video source i.e (camera). 

 

5.  LOOP 

Allows connection to other video devices  

 

6.  AUDIO INPUTS (1-4) 

Connects to an audio source for recording purposes (i.e. microphone) 

 

7.  AUDIO OUTPUTS (R/L) 

Connects to a speaker (or a monitor with audio speaker) 

 

8.  MONITOR 

Connects to main monitor 

 

9.  CALL 

Connects to the CALL monitor for real time sequencing. 

Summary of Contents for DXR116

Page 1: ...16 Channel Digital Video Recorder DXR116 FOR MORE INFORMATION WWW STRATEGICVISTA COM BEFORE OPERATING THIS SYSTEM PLEASE READ THIS MANUAL THOROUGHLY AND RETAIN IT FOR FUTURE REFERENCE...

Page 2: ...l environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio commu...

Page 3: ...e Protocol Setup 13 Search 14 Last Record 14 Full List 14 Alarm List 15 Time Search 15 Timer Recording Setup 15 Timer 15 Record Settings 17 HDD Overwrite Setup 17 Record IPS Setup 17 Record Quality Se...

Page 4: ...3 Appendix 5 Recording Times in Hours 34 Appendix 6 RS232 Remote Protocol 35 Appendix 7 Compatible HDD Brands 36 Limited Warranty 37 Care Maintenance 38...

Page 5: ...urning the power off correctly This equipment should be operated using only the power source from standard package Unauthorized repair or parts substitutions may result in fire electric shock or other...

Page 6: ...nputs and 2 outputs Resolution 704X564 full screen 352X282 4 channels 224X188 9 channels and 176X141 16 channels Independent main and call monitor outputs allow simultaneous or full screen viewing Mul...

Page 7: ...rical outlet A Red LED indicator light will be ON to indicate that the DVR is in Standby mode 3 Press the Power button The POWER LED will turn from red to orange and other red LED indicators will turn...

Page 8: ...ect the position of cameras in the multi camera display mode for more information see view select option in the operation section 8 Press to view the 4 channel screen display mode 9 Press to toggle be...

Page 9: ...has two functions i Pressing STOP terminates recording or playing The DXR116 returns to live monitoring mode and stops all other actions ii In Menu mode the STOP button is used to scroll down through...

Page 10: ...ects to a PC for Remote Control via RS 232 or to an Alarm Block see appendix 6 for more info 3 75 HI When using the LOOP function allows for HI impedance or 75ohms 4 VIDEO INPUT 1 16 Connects to a vid...

Page 11: ...red the main menu options will be displayed There are 6 options available in the Main Menu Search Finds recorded list Timer Scheduling Recording Record Record mode set up Camera Camera channel set up...

Page 12: ...al audible alarm buzzer Options are ON Buzzer is on When the DVR detects an alarm the system sounds the internal buzzer to alert the user OFF Buzzer is off 3 Press MENU to confirm your change 4 Press...

Page 13: ...ER 2 Press to enable or disable the Message Latch feature Options are NO Screen messages will disappear after a 10 sec this is the default setting YES On Screen messages will remain on the screen for...

Page 14: ...loss of all video and related data currently stored on the Hard Drive Resetting System to Factory Defaults Using the System Reset option will set all options back to factory default settings Use the s...

Page 15: ...h menu press to scroll to the Last Record option then press ENTER The last recorded video will begin playing Full List This Feature is used to choose from a listing of all recorded video on the HDD so...

Page 16: ...ould like the DVR to automatically record Pressing ENTER after scrolling to the Timer option will bring up the following menu options Timer 1 Press to select the day s to record on the available optio...

Page 17: ...g Timer Record feature NO To confirm no Timer Enable No Scheduling Timer Record feature 8 Press MENU to exit and confirm current operation 9 Press MENU again to exit and close TIMER setup mode NOTE WH...

Page 18: ...RECORD IPS setup mode Record Quality Setup 1 Press ENTER to confirm Record Quality setup 2 Press to choose Record Quality level BEST HIGH NORMAL BASIC 3 Press MENU to exit and confirm current operatio...

Page 19: ...is feature is used to enable or disable the dwell feature for each camera when viewing using the call monitor output 1 Press to select the desired time camera channel 1 16 then press ENTER 2 Press to...

Page 20: ...the recording time to that channel i e the normal record sequence for cameras is camera 1 camera 2 camera 3 etc In Event mode when an alarm in triggered from channel 1 the DVR will record using the fo...

Page 21: ...7 Press ENTER to turn the target cursor ON Press ENTER again to turn the target cursor OFF 8 Camera Select 1 15 toggles the corresponding target on the cursor line ON or OFF see Figure 1 1 There are o...

Page 22: ...N DETECTION SETUP 1 16 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 032 Figure 1 2 MOTION DETECTION SETUP LINE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 032 Figure 1 3 MOTION DETECTION SETUP ALL 1 2 3 4 5 6 7 8 9 10...

Page 23: ...vent scroll to the event and press ENTER The following is a list of events that can be displayed on the DXR116 M HDD WARNING Master HDD might be failed M HDD LOSS Master HDD does not exist User can us...

Page 24: ...ng the letter M Camera Select 1 16 Press Camera Select 1 16 button to select the desired camera to display in full screen mode View Select This button is used to select the ideal viewing configuration...

Page 25: ...ause during playback Press PAUSE the display will pause on the active screen If Stop is pressed during playback or during a pause the DXR116 will jump to the live monitoring mode Image jog dial To use...

Page 26: ...ck that Timer Alarm Enable is set to YES Timer Alarm recording isn t working Check if the system is in Key Lock mode Press MENU and ENTER at the same time to escape the Key Lock mode Buttons aren t wo...

Page 27: ...NTSC 100 IPS for PAL Recording refresh rate 25 IPS for NTSC 22 IPS for PAL Dwell time Programmable 1 10 Sec Picture in picture Yes Moveable Key lock Yes Picture zoom 2X Moveable Camera title 6 Charac...

Page 28: ...lease see step 8 for more information on locking and unlocking the removable HDD cartridge Step 2 Remove the Cover from the Cartridge Casing Step 3 Unclip the release latch with the word OPEN printed...

Page 29: ...idge Casing Slide the Cover forward over the Cartridge Case Ensure it is secured in place over the release latch Reinsert the Cartridge Casing into the DXR116 Step 8 Lock the Cartridge To Lock the cab...

Page 30: ...29 Appendix 2 Connection Diagram to Cameras and Monitor Alarm Input Video Camera 16 Main Monitor 2 1 RS232 PC Sensor Alarm Call Monitor AUDIO 4 CHANNEL...

Page 31: ...30 Appendix 3 Pin Configurations 9 pin com port External I O 25 pin com port...

Page 32: ...an alarm on Camera 12 which can activate the internal audible alarm and start recording PIN 9 ALARM INPUT 10 Used to connect an alarm sensor between ALARM INPUT 10 PIN9 and GND PIN 1 to trigger an ala...

Page 33: ...rm on Camera 11 which can activate the internal audible alarm and start recording PIN 22 ALARM INPUT 9 Used to connect an alarm sensor between ALARM INPUT 9 PIN 22 and GND PIN 1 to trigger an alarm on...

Page 34: ...ckets for rack mounting applications can be purchased as an optional accessory Front Angle with Rack Mount Side View with Rack Mount For more information about the rack mount other accessories through...

Page 35: ...600hr 1200hr 2400hr 4800hr HDD Type 240GB PAL SYSTEM IPS 12A 12 6 3 2 1 Best 24hr 50hr 101hr 203hr 304hr 608hr High 30hr 63hr 177hr 253hr 380hr 760hr Normal 49hr 101hr 203hr 405hr 606hr 1220hr Record...

Page 36: ...ENTER CH3 Key 0x33 3 4CUT Key 0x61 a CH4 Key 0x34 4 ZOOM Key 0x5A Z CH5 Key 0x35 5 9CUT Key 0x62 b CH6 Key 0x36 6 PIP Key 0x70 p CH7 Key 0x37 7 16CUT Key 0x63 c CH8 Key 0x38 8 SLOW Key 0x53 S CH9 Key...

Page 37: ...120GB 7200 rpm Maxtor DiamondMax 536DX 60GB 4W060H4 60GB 5400 rpm Maxtor DiamondMax Plus 9 Model 6Y120L 120GB 7200 rpm Seagate Barracuda ATA IV ST340016A 40GB 7200 rpm Seagate Barracuda ATA V ST312002...

Page 38: ...ng from the malfunctioning or non functioning of the Product or for any delay in the performance of this warranty due to any cause beyond its control This warranty shall not apply to the appearance or...

Page 39: ...l temperature environment Extreme temperatures can shorten the life of the electronic devices Handle the monitor carefully Dropping it can cause serious damage to the unit Occasionally clean the unit...