3.2  Health Protection and Safety

 

To ensure that our products are safe and do not pose a health hazard, the following points must be 

 observed:

 

1. 

Read all relevant sections of this manual carefully before starting work.

 

2. 

All warning signs on containers and packaging must be observed.

 

3. 

Installation, operation, maintenance and repair work may only be carried out by suitably trai- 

 

 

ned personnel and in accordance with the instructions given. If one of these instructions is not  

 

 

followed, the user of the product bears full responsibility for any consequences that may occur.

 

4. 

Disconnect the appliance from any power supply before opening it.

 

5. 

The safety instructions must be strictly observed in order to avoid damage to property and  

 

 

bodily injury - possibly even fatal ones.

 

3.3  Conversions and Changes

 

The device may not be modified in terms of design or safety without the express consent of Lorenz

 

 

Messtechnik GmbH. Any modification excludes any liability on our part for damages resulting there-

 

 

from. Repairs and modifications are prohibited.

 

3.4  CE Marking

 

 

With the CE marking, Lorenz Messtechnik GmbH guarantees that its product meets the requirements  

 

of the relevant EC directives. 

4 Preamble

 

4.1  Product Description

 

The SI-RS485 is an amplifier which processes analogous measured values and converts these sig-

 

 

nals into digital signals. These measured data can be retrieved by the PC by means of the RS485-Inter- 

 

face. The current supply occurs via a separate power supply which is included in delivery.

 

Required output voltage: 

12 ... 30V

 

Required power supply: 

600 mA

 

The SI-RS485 is suitable for the connection and simultaneous value acquisition of two sensors. De- 

 

pending on the SI-RS485 model, respectively four different types of sensor signals can be captured 

 

 

(for specifications see data sheet):

 

Strain gauge signals:   

 

±3 mV/V 

 

(corresponds ±30000 digits)

 

Active signals with voltage input: 

±5V   

 

(corresponds ±25000 digits)

 

Active signals with voltage input: 

±10V   

 

(corresponds ±25000 digits)

 

Active signals with current input: 

0 ... 20 mA 

 

(corresponds 0 ... 20000 digits)

 

Active signals with current input: 

4 ... 20 mA 

 

(corresponds 0 ... 20000 digits)

 

 

The amplifier type and the resolution are stated on the type label, a type change is only possible by 

 

 

the manufacturer. Hence, only the corresponding sensor type can be connected.

Summary of Contents for SI-RS485

Page 1: ...73553 Alfdorf Phone 49 7172 93730 0 Fax 49 7172 93730 22 info lorenz messtechnik de www lorenz messtechnik de Technical changes errors and misprints excepted 090325c_SI RS485 1 13 Amplifiers Operatin...

Page 2: ...ect Use 7 5 Technical Details 7 5 1 Configuration of the Connections 7 5 2 Adjustment of the Second Order Low Pass Filter for each Sensor Channel 7 5 2 1 Changing via VS3 7 5 2 2 Changing via LCV USB...

Page 3: ...who are familiar with the installation operation maintenance and repair of the device and have the appro priate qualifications The personnel must have knowledge of the legal and safety regulations and...

Page 4: ...must be ensured that a the device its malfunction or its failure does not lead to damage to property or a loss of that can lead to danger to people It is also important to prevent the precautions that...

Page 5: ...the operating instructions and in particular the safety instructions Incorrect use e g by untrained personnel may result in residual hazards The operating instructions must be read and understood by a...

Page 6: ...ation excludes any liability on our part for damages resulting there from Repairs and modifications are prohibited 3 4 CE Marking With the CE marking Lorenz Messtechnik GmbH guarantees that its produc...

Page 7: ...value tare value minimal value and maximal value Presentation of the measured data in a diagram Storage of measured data in CSV format output configurable Storage of the diagram in BMP format output s...

Page 8: ...rther information regarding programming with own software we refer to document 090110 Lorenzprotocol A flexible command set for digital sensors and interfaces 6 Pin Assignments 6 1 Pin Assignment for...

Page 9: ...lti component sensor M 2354 is directly connec ted to the SI RS485 DMS DMS with both outputs The system allows simultaneous recording of force torque courses which chronologically refer to each other...

Page 10: ...ch other 8 Debugging This chart helps to find frequent errors and the measures for debugging Error Possible Cause Debugging A connection to the SI RS485 is not possible Power supply not connected Conn...

Page 11: ...0 mA Measured values 30000 digits 25000 digits 30000 digits 0 20000 digits 25000 digits 25000 digits 0 20000 digits 25000 digits 0 20000 digits Resolution 1 mV V 10000 digits 1V 2500 digits 1 mV V 100...

Page 12: ...nditions of Delivery and Sale at www lorenz messtechnik de Article No Description Type 115134 Adjustment amplifier with simulator mV V 10V 0 4 20 mA 113591 Input range 4 5 mV V per channel LCV USB3 SI...

Page 13: ...changes errors and misprints excepted 090325c_SI RS485 13 13 11 Reference Information Document number 090324 operation manual German Document number 080997 data sheet German 080996 Document number 090...