Filter:
At a high filter effect, interferences are better suppressed, however, a fast
dynamic measurement is not possible.
At a low filter effect, fast measurements are possible, but interferences
must be reduced by other appropriate measures such as grounding, cable
shielding etc.
6.7
Troubleshooting
No Output Signal available:
- No supply voltage _ Power LED must be on.
- Sensor not connected or open circuit in the sensor cable?
Voltage or current output in control limit:
- Signal input is not connected or wrongly connected?
- Open circuit in the sensor cable.
- Was the sensor overloaded?
Output signal does not go back to 0:
- Was the sensor overloaded?
- Was the sensor installed tensed?
- Control switch on “ON”?
- Was the sensor connected correctly?
- Open circuit in the sensor cable?
Current output is not linear:
- Nominal impedance of max. 500 Ohm was exceeded.