if the threshold alarm is activated
MEASURE:
Choice of monitored measure type.
VOLTAGE?
Push the
YES
button to choose the displayed type. Push the
NO
button to display the
next type.
HIGH THRESHOLD?
Choose the type of detection (High or Low, see
p10
).
LOW THRESHOLD?
THRESHOLD?
Push the
YES
button to access the threshold value setting.
RELAY CLOSED IN ALARM?
Choose the type of security (see
p10
).
RELAY CLOSED OUT OF ALARM?
ALARM HOLD?
YES
to activate the hold function,
NO
to deactivate it.
ACTIVATION DELAY?
Push the
YES
button to access the activation delay setting.
DEACTIVATION DELAY? Push the
YES
button to access the deactivation delay setting. Absent if the alarm
hold function is enabled.
or if the window alarm is activated
MEASURE:
Choice of monitored measure type.
VOLTAGE?
Push the
YES
button to choose the displayed type. Push the
NO
button to display the
next type.
LOW THRESHOLD?
Push the
YES
button to access the low threshold value setting.
HIGH THRESHOLD?
Push the
YES
button to access the high threshold value setting.
RELAY CLOSED IN THE WINDOW?
Choose the functioning mode (see
p11
).
RELAY CLOSED OUT OF WINDOW?
ACTIVATION DELAY?
Push the
YES
button to access the activation delay setting.
DEACTIVATION DELAY? Push the
YES
button to access the deactivation delay setting. Absent if the alarm
hold function is enabled.
RELAY 2?
Push the
YES
button to access to the relay 2 configuration (only with /R2 option).
same as relay 1
RELAY 3?
Push the
YES
button to access to the relay 3 configuration (only with /R3 option).
same as relay 1
4.5) Output configuration
OUTPUTS CONFIG?
Push the
YES
button to access to the rubric.
OUTPUT 1?
Push the
YES
button to access to the output 1 configuration.
CURRENT?
Choose the output type, current or voltage.
VOLTAGE?
OUTPUT 0%?
Push the
YES
button to access the output low scale setting.
OUTPUT 100%?
Push the
YES
button to access the output high scale setting.
RESPONSE TIME?
Push the
YES
button to access the output response time setting (0 to 60 s).
LIMITATION?
Push the
YES
button to activate the output limitation, Push the
NO
button to
deactivate the output limitation.