V-Link
®
-200
User Manual
2.3
Node Diagnostics
In the Wireless Node Configuration menu under the Sampling tab, there are four user-set data points
to provide information about the status of the Node.
Figure 3 - Node Diagnostic Menu
l
Lost Beacon Timeout: The time a node will search for a beacon before determining there
is no base station connectivity. User-set between 2 minutes and 600 minutes
l
Diagnostic Info Interval: The report rate of the diagnostic packet. User-set between 30
seconds and 65536 seconds. The following data channels are available.
o
Current State: The current state of the device when the Diagnostic
Packet is sent.
o
0 = Idle
o
1 = Deep Sleep
o
2 = Active Run
o
3 = Inactive Run
o
Run Time: The number of seconds the Node has been in each state.
o
Reset Counter: The number of times the Node has reset.
o
Low Battery Indicator: If 1, a low battery event has been detected
since the last Diagnostic Packet.
o
Sample Info:
o
Sweep Index: The total number of sweeps (good
and bad).
10