NOTE
When selecting sensor and estimation outputs to be recorded, communications bandwidth
considerations should be taken into account. Lower baud rates equate to lower
communications bandwidth, which can be consumed quickly by selecting a large number of
measurements at high sample rates. Overrunning the communications bandwidth will result
in dropped communications packets and lost data.
3.5.1
Saving Configurations
Sensor settings are saved temporarily by selecting the OK button in the Device Setup window after
configuration, but they are lost when the device is powered off. To save current settings, so they are
automatically restored the next time the device is powered on, select Settings > Save Current
Settings.
First adjust the sensor settings to the desired values. Next select Settings > Save Current Settings
from the main window (
Figure 10 - Save Sensor Settings
). The settings will now remain intact when
the sensor is powered off and then on again.
To recall the last saved settings select Settings > Load Startup Settings. To revert the settings back
to the factory defaults, select Settings > Load Default Settings.
Figure 10 -Save Sensor Settings