Messages
- 48 -
01.21
909.2669.9-02
17.2
Error messages
If the error occurs again, an inspection or repair
by the service office is necessary.
Code
Error
Cause
Possible remedy
E01-01
Thermal overload secondary
diode
Duty cycle exceeded
Allow switched-on machine to cool down for a
few minutes.
E01-02
Thermal overload primary mod-
ule
E01-03
Thermal overload transformer
E01-05
Thermal overload PFC
E02-00
Overvoltage mains
Mains voltage too high
Check mains voltage
E04-01
PE conductor monitoring
Fault current to protective earth conductor Check connection of the workpiece cable and
ground clip
E05-00
Water pump (in water-cooled
operation)
Connection cable or machine water cool-
ing circuit defective
Check and replace Lorchnet cable or machine
water cooling
Torch monitor (in gas-cooled
operation)
Incorrect torch connected (water-cooled
torch)
Use gas-cooled torch (recognised by bridge be-
tween the contacts 4 and 5 on the torch plug)
E06-00
Overvoltage secondary
Initial voltage too high
Inform Service
E09-00
Voltage detection
Error at voltage detection
E09-01
Voltage detection plug socket
Error at the voltage detection module 2
E10-00
Torch/remote control
Remote control, torch or connections
defective
Check or replace torch and remote control
E10-01
Thermal overload torch
Torch stressed beyond-design limit
Allow torch to cool down for a few minutes
E12-00
Power section
Power section start-up faulty
Inform Service
E13-01
Temperature sensor secondary
diode
Thermal sensor defective
E13-02
Temperature sensor primary
module
E13-03
Temperature sensor transformer
E13-04
Temperature sensor PFC
E14-00
Supply voltage
Fault internal supply voltage
E15-00
Current detection
Error at the current detection
E16-00
Overcurrent protective switch off Current consumption of power unit too
high
E19-00
Ignition device
Ignition unit faulty
E22-00
Low voltage mains
Mains voltage too low
Check mains voltage
E25-00
Voltage Reduction Device (VRD)
Voltage Reduction Device defective or
short circuit between workpiece and torch
Torches and electrode holders must not have
electrical contact to the ground cable (short
circuit) when switched on
E30-00
Error configuration
Wrong or broken pc-board, wrong system-
software was flashed
Inform Service
E30-03
User panel identification
User panel identification error
E33-01
Power unit
Power unit not symmetrical
E34-00
Fan
Fan current to high
Tab. 10:
Error messages
ii
Summary of Contents for T 180 AC BasicPlus
Page 11: ...Vor der Inbetriebnahme 11 01 21 909 2669 9 02 ...
Page 35: ...Before commissioning 35 01 21 909 2669 9 02 ...
Page 59: ...Antes de la puesta en marcha 59 01 21 909 2669 9 02 ...
Page 83: ...Voor de inbedrijfstelling 83 01 21 909 2669 9 02 ...
Page 107: ...Перед вводом в эксплуатацию 107 01 21 909 2669 9 02 ...
Page 131: ...Przed uruchomieniem 131 01 21 909 2669 9 02 ...
Page 155: ...Antes de colocar em funcionamento 155 01 21 909 2669 9 02 ...
Page 179: ...Avant la mise en service 179 01 21 909 2669 9 02 ...
Page 203: ...Před uvedením do provozu 203 01 21 909 2669 9 02 ...
Page 227: ...Prima di cominciare 227 01 21 909 2669 9 02 ...