Troubleshooting
- 61 -
02.20
909.2710.1-06
9.11 Encoding power units
During the initialisation of the machine (switching on), the MAPRO pcb is detecting what power units are
connected. The identification of the power units is made by a DIP switch at the DCDR pcbs. Should the
MAPRO detect that the configuration is not valid, it will stop and displays
E25
(Power module detection).
Schematic
DIP1 DIP2 setting
type
OFF
OFF
240A
S5 / P4500
OFF
ON
350A
S3 / P3x00
ON
OFF
300A
S8 / P5500
ON
ON
reserved
Tab. 34:
Power unit configuration