20
Operating Your Appliance
© Travis Industries
100-01163
4041129
Troubleshooting
Problem
Possible Cause
Smoke Enters Room During
Start-Up
Open the bypass (pg. 15).
Open the air control (pg. 17).
Cold Air Blockage - burn a piece of newspaper to
establish a draft.
If the flame is not getting enough air, a small crack in
the door is all that is needed.
Kindling Does Not Start - Fire
Smolders
Open the bypass (pg. 15).
Open the air control (pg. 17).
Not enough starter paper - use additional newspaper if
necessary.
If the flame is not getting enough air, a small crack in
the door is all that is needed.
Smoke Enters Room While Re-
Loading
Open the bypass before opening the door (pg. 15).
Open the air control before opening the door (pg. 17).
Let the air stabilize before fully opening the door.
Then open the door approximately 1 inch. Let air go
into the firebox for a few seconds. Once the smoke
appears to be flowing up the chimney consistently,
open the door.
Insufficient Draft - Chimney height and outside
conditions can negatively affect draft. In these cases a
small amount of smoke may enter the home. Adding
more pipe or a draft-inducing cap may help.
Stove Does Not Burn Hot Enough
Wood is Wet - see the section "Selecting Wood" on
page 19 for details on wood.
Make sure the air control is all the way open. Slide the
control back and forth to insure the control is not stuck.
Insufficient Draft - Chimney height and outside
conditions can negatively affect draft. In these cases
the fire may burn slowly. Adding more pipe or a draft-
inducing cap may help.
Blower Does Not Run
Stove is Not Up to Temperature - This is normal. The
blower will come on when the stove is hot - usually 15
to 30 minutes.
Electricity is Cut to the Blower - Check the household
breaker or fuse to make sure it is operable.